Lorentz PS200 HR C
Solar Operated Submersible Pump System, 4”
Helical Rotor (HR) or Centrifugal (C) Pump Unit
Characteristics
|
Application
|
Components
Controller PS200
Pump End (PE)
|
Motor ECDRIVE 600 HR / 200 C
For HR Pumps Only
|
[/vc_column_text][/vc_column][vc_column width=”1/3″][contact-form-7 id=”2456″][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
Performance
PS200 | HR-04 | HR-07 | HR-14 | C-5-4 |
---|---|---|---|---|
article # | 1007-X | 1009-X | 1008-X | 1205 |
lift [m] | 0-50 | 0-30 | 0-20 | 0-15 |
max. flow rate [m3/h] | 0.8 | 1.2 | 2.7 | 5.0 |
max. efficiency [%] | 60 | 61 | 62 | 45 |
solar operation | solar operation nominal voltage 24-48 V DC open circuit voltage max. 100 V DC |
battery operation only | ||
solar generator [Wp] | 80-300 | 80-300 | 80-300 | |
battery operation | nominal voltage 24-48 V DC |
System Sizing Table: Battery Operation
PS200 HR, 24 V, Battery Operation | PS200 HR, 48 V, Battery Operation | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
vertical lift | pump type | peak flow rate | power | wire size | vertical lift | pump type | peak flow rate | power | wire size | ||||
[m] | [ft] | [l/min] | [US Gal./min] | [W] | [mm²] | [m] | [ft] | [l/min] | [US Gal./min] | [W] | [mm2] | ||
5 | 16 | HR-04 HR-07 HR-14 |
5.5 7.5 17.5 |
1.5 2.0 4.6 |
24 37 40 |
2.5 | 5 | 16 | HR-04 HR-07 HR-14 |
11.0 17.038.4 |
2.9 4.5 10.1 |
55 90 130 |
2.5 |
10 | 33 | HR-04 HR-07 HR-14 |
5.2 7.5 16.6 |
1.4 2.0 4.4 |
29 42 55 |
2.5 | 10 | 33 | HR-04 HR-07 HR-14 |
10.3 16.5 36.1 |
2.7 4.4 9.5 |
70 100 165 |
2.5 |
15 | 50 | HR-04 HR-07 HR-14 |
4.8 7.0 15.2 |
1.3 1.8 4.0 |
34 50 74 |
2.5 | 15 | 50 | HR-04 HR-07 HR-14 |
10.1 15.8 35.0 |
2.7 4.2 9.2 |
80 115 195 |
2.5 |
20 | 65 | HR-04 HR-07 HR-14 |
4.5 6.5 12.5 |
1.2 1.7 3.3 |
38 60 91 |
2.5 | 20 | 65 | HR-04 HR-07 |
9.8 15.5 |
2.6 4.1 |
90 135 |
2.5 |
30 | 100 | HR-04 | 4.2 | 1.1 | 48 | 4.0 | 30 | 100 | HR-04 HR-07 |
9.3 14.2 |
2.5 3.8 |
105 160 |
4.0 |
40 | 130 | HR-04 | 3.8 | 1.0 | 58 | 4.0 | 40 | 130 | HR-04 HR-07 |
8.7 13.5 |
2.3 3.6 |
125 190 |
4.0 |
50 | 165 | HR-04 | 3.3 | 0.9 | 65 | 4.0 | 50 | 165 | HR-04 | 7.8 | 2.1 | 140 | 4.0 |
PS200 C-5-4, 24 V to 48 V, Battery Operation | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
20 V | 24 V | 26-48 V | |||||||||||
lift | power | flow rate | power | flow rate | power | flow rate | |||||||
[m] | [ft] | [W] | [l/min] | [US Gal./min] | [Imp. Gal./min] | [W] | [l/min] | [US Gal./min] | [Imp. Gal./min] | [W] | [l/min] | [US Gal./min] | [Imp. Gal./min] |
2.50 | 8 | 130 | 52 | 13.7 | 11.4 | 192 | 62 | 16.4 | 13.6 | 278 | 65 | 17.2 | 14.3 |
5 | 16 | 140 | 43 | 11.4 | 9.5 | 206 | 55 | 14.5 | 12.1 | 278 | 63 | 16.6 | 13.9 |
8 | 26 | 140 | 38 | 10.0 | 8.4 | 206 | 49 | 12.9 | 10.8 | 278 | 59 | 15.6 | 13.0 |
10 | 33 | 132 | 31 | 8.2 | 6.8 | 205 | 45 | 11.9 | 9.9 | 276 | 55 | 14.5 | 12.1 |
13 | 43 | 130 | 20 | 5.3 | 4.4 | 204 | 39 | 10.3 | 8.6 | 270 | 50 | 13.2 | 11.0 |
15 | 49 | 120 | 10 | 2.6 | 2.2 | 200 | 34 | 9.0 | 7.5 | 268 | 45 | 11.9 | 9.9 |
18 | 59 | 190 | 25 | 6.6 | 5.5 | 247 | 35 | 9.2 | 7.7 | ||||
wire size | use min 4 mm² / AWG #10 cable; max. length 15 m / 50 ft |
For Battery and Solar Direct Systems
[/vc_column_text][vc_row_inner][vc_column_inner width=”1/3″][vc_column_text]
Lift Limits
These systems are selected for optimum performance. To allow unexpected drawdown, each system can handle an additional 15 % lift.
Higher Lift? Higher Flow Rate?
Choose PS600/1200 for higher lift, higher flow rate applications and lower cable cost.[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/3″][vc_column_text]
Wire Sizes
Cable Layout is calculated to stay within 4 % power loss.
Variations of Length
Longer: for each 50 % increase, the next larger wire size is required
Shorter: for each 33 % decrease, the next smaller wire size is required
Array To Controller: if shorter than 6 m / 20 ft: 4 mm2 / #10 min.
Controller To Low-Water Probe: 1 mm2/#18 min. 2-conductor[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/3″][vc_column_text]
Conversion For Flow
1 m3 = 264 US Gal.
1 m3 = 220 Imp. Gal.
1 l/min = 0.264 US Gal./min
1 l/min = 0.220 Imp. Gal./min
Conversion For Lift / Length
1 m = 3.3 ft
Conversion For Wire Sizes
AWG | mm2 |
---|---|
# 18 | 1 |
# 12 | 4 |
# 10 | 6 |
# 8 | 10 |
# 6 | 16 |
Table shows nearest larger metric cross section[/vc_column_text][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner width=”1/1″][vc_column_text]
System Sizing Table: Solar Operation
PS200 HR, 24 V
nominal voltage, 2 standard 12 V modules wired in series[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]
irradiation: 4.0 kWh/m2/day, tilted surface | |||||||
---|---|---|---|---|---|---|---|
vertical lift | pump type | peak flow rate | flow rate for PV array power peak [m³/day] | wire size | |||
[m] | [ft] | [l/min] | 80 Wp | 120 Wp | 150 Wp | [mm²] | |
5 | 16 | HR-04 HR-07 |
7.2 13.0 |
2.2 2.0 |
2.5 3.5 |
2.8 4.7 |
2.5 |
10 | 33 | HR-04 HR-07 |
6.5 13.0 |
2.0 1.7 |
2.3 3.0 |
2.6 4.2 |
2.5 |
15 | 50 | HR-04 HR-07 |
6.0 12.0 |
1.8 1.5 |
2.0 2.8 |
2.4 3.9 |
2.5 |
20 | 65 | HR-04 HR-07 |
5.8 12.0 |
1.4 1.1 |
1.6 2.5 |
2.2 3.7 |
2.5 |
25 | 82 | HR-04 | 5.7 | 1.1 | 1.5 | 2.1 | 2.5 |
30 | 100 | HR-04 | 5.5 | 0.8 | 1.2 | 2.0 | 2.5 |
40 | 130 | HR-04 | 5.1 | 1.0 | 1.8 | 4.0 | |
50 | 165 | HR-04 | 5.1 | see 36-48V table | 4.0 |
[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]
irradiation: 6.0 kWh/m2/day, tilted surface | |||||||
---|---|---|---|---|---|---|---|
vertical lift | pump type | peak flow rate | flow rate for PV array power peak [m³/day] | wire size | |||
[m] | [ft] | [l/min] | 80 Wp | 120 Wp | 150 Wp | [mm²] | |
5 | 16 | HR-04 HR-07 |
7.2 13.0 |
3.5 |
3.8 |
4.0 |
2.5 |
10 | 33 | HR-04 HR-07 |
6.5 13.0 |
3.3 3.9 |
3.6 5.2 |
4.0 5.4 |
2.5 |
15 | 50 | HR-04 HR-07 |
6.0 12.0 |
2.9 3.5 |
3.5 5.0 |
4.0 5.2 |
2.5 |
20 | 65 | HR-04 HR-07 |
5.8 12.0 |
2.5 2.4 |
3.3 3.8 |
3.9 4.9 |
2.5 |
25 | 82 | HR-04 | 5.7 | 2.2 | 3.0 | 3.5 | 2.5 |
30 | 100 | HR-04 | 5.5 | 1.9 | 2.8 | 3.1 | 2.5 |
40 | 130 | HR-04 | 5.1 | 2.0 | 2.5 | 4.0 | |
50 | 165 | HR-04 | 5.1 | see 36-48V table | 4.0 |
[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
PS200 HR, 36-38 V
nominal voltage, 3 to 4 standard 12 V modules wired in series[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]
irradiation: 4.0 kWh/m2/day, tilted surface | |||||||
---|---|---|---|---|---|---|---|
vertical lift | pump type | peak flow rate | flow rate for PV array power peak [m³/day] | wire size | |||
[m] | [ft] | [l/min] | 150 Wp | 200 Wp | 250 Wp | [mm²] | |
5 | 16 | HR-04 HR-07 |
12.0 19.5 |
4.8 4.7 |
5.4 7.0 |
6.4 8.5 |
2.5 |
10 | 33 | HR-04 HR-07 |
11.8 |
4.5 4.2 |
5.0 6.0 |
6.0 7.5 |
2.5 |
15 | 50 | HR-04 HR-07 |
11.5 |
4.0 3.9 |
4.6 6.0 |
5.7 7.4 |
2.5 |
20 | 65 | HR-04 HR-07 |
11.5 |
3.5 3.3 |
4.2 5.5 |
5.4 7.0 |
2.5 |
25 | 82 | HR-04 HR-07 |
11.3 |
2.6 X |
3.6 2.5 |
5.1 4.0 |
2.5 |
30 | 100 | HR-04 |
11.0 |
2.0 | 3.0 | 4.8 | 2.5 |
40 | 130 | HR-04 | 11.0 | 1.7 | 2.4 | 3.5 | 4.0 |
50 | 165 | HR-04 | 10.5 | 1.3 | 2.0 | 3.0 | 4.0 |
[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]
irradiation: 6.0 kWh/m2/day, tilted surface | |||||||
---|---|---|---|---|---|---|---|
vertical lift | pump type | peak flow rate | flow rate for PV array power peak [m³/day] | wire size | |||
[m] | [ft] | [l/min] | 150 Wp | 200 Wp | 250 Wp | [mm²] | |
5 | 16 | HR-04 HR-07 HR-14 |
12.0 19.5 36.0 |
6.3 8.5 11.0 |
6.6 9.5 15.0 |
7.3 10.5 18.0 |
2.5 |
10 | 33 | HR-04 HR-07 HR-14 |
11.8 19.0 34.0 |
6.0 8.0 9.0 |
6.5 9.0 13.0 |
7.0 10.0 16.0 |
2.5 |
15 | 50 | HR-04 HR-07 HR-14 |
11.5 18.5 33.0 |
5.5 7.0 8.0 |
6.0 8.3 11.0 |
6.8 9.5 14.0 |
2.5 |
20 | 65 | HR-04 HR-07 |
11.5 18.0 |
5.5 6.0 |
6.2 7.5 |
6.6 9.0 |
2.5 |
25 | 82 | HR-04 HR-07 |
11.3 17.5 |
5.0 5.0 |
5.6 6.5 |
6.2 8.0 |
2.5 |
30 | 100 | HR-04 | 11.0 | 4.3 | 4.9 | 5.8 | 2.5 |
40 | 130 | HR-04 | 11.0 | 3.0 | 4.0 | 5.0 | 4.0 |
50 | 165 | HR-04 | 10.5 | 2.0 | 3.0 | 4.2 | 4.0 |
[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
For Solar Direct Systems
System Voltage
24-48 V nominal, e.g. 2 to 4 standard 12 V modules wired in series, Voc 100 V max.
How Daily Water Volume Is Calculated
Daily volume is calculated by integrating real flow versus realistic solar (PV) output through the day. The solar array is fixed at tilt angle = latitude of the location.
irradiation: kWh/m²/day = peak sun hours/day
Flow rates may vary +/- 10 %.
Technical Data, Dimensions And Weights
Dimensions | Shipping Dimensions | ||||||||
---|---|---|---|---|---|---|---|---|---|
Pump Unit (PU) (motor + pump end) |
L | A | B | D | S | packaging | shipping volume | net weight | gross weight |
[mm] | [mm] | [mm] | [mm] | [mm] | [m³] | [kg] | [kg] | ||
HR-04 | 780 | 595 | 185 | 96 | G1¼” | 850x160x150 | 0.0204 | 11.2 | 12.0 |
HR-07, HR-14 | 771 | 586 | 185 | 96 | G1¼” | 850x160x150 | 0.0204 | 11.5 | 12.3 |
C-5-4 | 527 | 342 | 185 | 96 | G1¼” | 660x160x150 | 0.0158 | 10.0 | 10.5 |
Controller Type | |||||||||
PS200 | 320x240x160 | 0.0123 | 1.2 | 1.8 |
[/vc_column_text][vc_row_inner][vc_column_inner width=”1/3″][vc_column_text]
Sand And Silt Tolerance
The pump (HR) has a higher resistance to wear from sand, clay etc. than any other pump type. In properly constructed wells the amount of sand, clay etc. is within the tolerance of the pump.
A concentration of solids greater than 2 % (by volume) may cause blockage in the pump or the drop pipe, especially at low flow rates.
Do not use the pump to clean out a dirty well.[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/3″][vc_column_text]
Pump Cable And Splice
Standard submersible cable, 3-wire + ground (total four wires). Connection to the pump is made using industry-standard splicing methods.
Drop Pipe
G1¼” (optionally 1” NPT) pump outlet. If water is dirty, consider a smaller size drop pipe to increase the flow velocity. This helps exhaust solid particles and prevent accumulation in the pipe. When considering reduced pipe size, consult a pipe sizing (friction loss) chart. Pipe can be of any standard material, rigid or flexible. A torque arrestor is not required.[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/3″][vc_column_text]
Temperature Limits
Pump end, motor: water temperature up to +40° C (+104° F).
Specify temperature range on order.
Controller: ambient temperature -30° C to +55° C (-22° F to +131° F).
Warranty
Two years manufacturer’s warranty against defects in material and workmanship.[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row]