Fronius Symo Inverters
Maximum flexibility for the applications of tomorrow.
Boasting power categories ranging from 3.0 to 20.0 kW, the transformerless Fronius Symo is the three-phase inverter for systems of every size. The high system voltage, wide input voltage range and two MPP trackers ensure maximum flexibility in system design. The standard interface to the internet via WLAN or Ethernet and the ease of integration of third-party components make the Fronius Symo one of the most communicative inverters on the market.
[/vc_column_text][vc_row_inner][vc_column_inner width=”1/1″][vc_column_text]
TECHNICAL DATA FRONIUS SYMO (3.0-3-S, 3.7-3-S, 4.5-3-S, 3.0-3-M, 3.7-3-M, 4.5-3-M)
INPUT DATA | SYMO 3.0-3-S | SYMO 3.7-3-S | SYMO 4.5-3-S | SYMO 3.0-3-M | SYMO 3.7-3-M | SYMO 4.5-3-M |
---|---|---|---|---|---|---|
Max. input current (Idc max 1 / Idc max 2 1)) | 16.0 A / 16.0 A | |||||
Max. array short circuit current (MPP1/MPP2 1)) | 24.0 A / 24.0 A | |||||
Min. input voltage (Udc min) | 150 V | |||||
Feed-in start voltage (Udc start) | 200 V | |||||
Nominal input voltage (Udc,r) | 595 V | |||||
Max. input voltage (Udc max) | 1,000 V | |||||
MPP voltage range (Umpp min – Umpp max) | 200 – 800 V | 250 – 800 V | 300 – 800 V | 150 – 800 V | ||
Number MPP trackers | 1 | 2 | ||||
Number of DC connections | 3 | 2 + 2 |
OUTPUT DATA | SYMO 3.0-3-S | SYMO 3.7-3-S | SYMO 4.5-3-S | SYMO 3.0-3-M | SYMO 3.7-3-M | SYMO 4.5-3-M |
---|---|---|---|---|---|---|
AC nominal output (Pac,r) | 3,000 W | 3,700 W | 4,500 W | 3,000 W | 3,700 W | 4,500 W |
Max. output power | 3,000 VA | 3,700 VA | 4,500 VA | 3,000 VA | 3,700 VA | 4,500 VA |
Max. output current (Iac max) | 9.0 A | 13.5 A | ||||
Grid connection (Uac,r) | 3~NPE 400 V / 230 V or 3~NPE 380 V / 220 V | |||||
Min. output voltage (Uac min) | 260 / 150 V | |||||
Max. output voltage (Uac max) | 485 / 280 V | |||||
Frequency (fr) | 50 Hz / 60 Hz | |||||
Frequency range (fmin – fmax) | 45 – 65 Hz | |||||
Total harmonic distortion | < 3 % | |||||
Power factor (cos φac,r) | 0.70 – 1 ind. / cap. | 0.85 – 1 ind. / cap. |
[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][vc_column width=”1/3″][contact-form-7 id=”2456″][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
GENERAL DATA | SYMO 3.0-3-S | SYMO 3.7-3-S | SYMO 4.5-3-S | SYMO 3.0-3-M | SYMO 3.7-3-M | SYMO 4.5-3-M |
---|---|---|---|---|---|---|
Dimensions (height x width x depth) | 645 x 431 x 204 mm | |||||
Weight | 16.0 kg | 19.9 kg | ||||
Degree of protection | IP 55 | |||||
Protection class | 1 | |||||
Overvoltage category (DC / AC) 2) | 2 / 3 | |||||
Night time consumption | < 1 W | |||||
Inverter design | Transformerless | |||||
Cooling | Regulated air cooling | |||||
Installation | Indoor and outdoor installation | |||||
Ambient temperature range | -25 – +60 °C | |||||
Permitted humidity | 0 – 100 % | |||||
DC connection technology | 3x DC+ and 3x DC- screw terminals 2.5 – 16 mm2 | 4x DC+ and 4x DC- screw terminals 2.5 – 16mm2 3) | ||||
Mains connection technology | 5-pole AC screw terminals 2.5 – 16 mm2 | 5-pole AC screw terminals 2.5 – 16mm2 3) | ||||
Certificates and compliance with standards | DIN V VDE 0126-1-1/A1, VDE AR N 4105, IEC 62109-1/-2, IEC 62116, IEC 61727, AS 3100, AS 4777-2, AS 4777-3, 1) CER 06-190, G83/2, UNE 206007-1, SI 4777 1), CEI 0-21 |
1) This applies to Fronius Symo 3.0-3-M, 3.7-3-M and 4.5-3-M
2) according to IEC 62109-1.
3) 16 mm2 without wire end ferrules.[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]
Fronius SYMO 4.5-3-S EFFICIENCY CURVE
[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]
Fronius SYMO 4.5-3-S TEMPERATURE DERATING
[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
TECHNICAL DATA FRONIUS SYMO (3.0-3-S, 3.7-3-S, 4.5-3-S, 3.0-3-M, 3.7-3-M, 4.5-3-M)
EFFICIENCY | SYMO 3.0-3-S | SYMO 3.7-3-S | SYMO 4.5-3-S | SYMO 3.0-3-M | SYMO 3.7-3-M | SYMO 4.5-3-M |
---|---|---|---|---|---|---|
Max. efficiency | 98.0 % | |||||
European efficiency (ηEU) | 96.2 % | 96.7 % | 97.0 % | 96.5 % | 96.9 % | 97.2 % |
η at 5 % Pac.r 1) | 80.3 / 83.6 / 79.1 % | 83.4 / 86.4 / 80.6 % | 84.8 / 88.5 / 82.8 % | 79.8 / 85.1 / 80.8 % | 81.6 / 87.8 / 82.8 % | 83.4 / 90.3 / 85.0 % |
η at 10 % Pac.r 1) | 87.8 / 91.0 / 86.2 % | 90.1 / 92.5 / 88.7 % | 91.7 / 93.7 / 90.3 % | 86.5 / 91.6 / 87.7 % | 87.9 / 93.6 / 90.5 % | 89.2 / 94.1 / 91.2 % |
η at 20 % Pac.r 1) | 92.6 / 95.0 / 92.6 % | 93.7 / 95.7 / 93.6 % | 94.6 / 96.3 / 94.5 % | 90.8 / 95.3 / 93.0 % | 91.9 / 96.0 / 94.1 % | 92.8 / 96.5 / 95.1 % |
η at 25 % Pac.r 1) | 93.4 / 95.6 / 93.8 % | 94.5 / 96.4 / 94.7 % | 95.2 / 96.8 / 95.4 % | 91.9 / 96.0 / 94.2 % | 92.9 / 96.6 / 95.2 % | 93.5 / 97.0 / 95.8 % |
η at 30 % Pac. 1) | 94.0 / 96.3 / 94.5 % | 95.0 / 96.7 / 95.4 % | 95.6 / 97.2 / 95.9 % | 92.8 / 96.5 / 95.1 % | 93.5 / 97.0 / 95.8 % | 94.2 / 97.3 / 96.3 % |
η at 50 % Pac.r 1) | 95.2 / 97.3 / 96.3 % | 96.9 / 97.6 / 96.7 % | 96.4 / 97.7 / 97.0 % | 94.3 / 97.5 / 96.5 % | 94.6 / 97.7 / 96.8 % | 94.9 / 97.8 / 97.2 % |
η at 75 % Pac.r 1) | 95.6 / 97.7 / 97.0 % | 96.2 / 97.8 / 97.3 % | 96.6 / 98.0 / 97.4 % | 94.9 / 97.8 / 97.2 % | 95.0 / 97.9 / 97.4 % | 95.1 / 98.0 / 97.5 % |
η at 100 % Pac.r 1) | 95.6 / 97.9 / 97.3 % | 96.2 / 98.0 / 97.5 % | 96.6 / 98.0 / 97.5 % | 95.0 / 98.0 / 97.4 % | 95.1 / 98.0 / 97.5 % | 95.0 / 98.0 / 97.6 % |
MPP adaptation efficiency | > 99.9 % |
1) and at Umpp min / Udc.r / Umpp max
PROTECTIVE DEVICES | SYMO 3.0-3-S | SYMO 3.7-3-S | SYMO 4.5-3-S | SYMO 3.0-3-M | SYMO 3.7-3-M | SYMO 4.5-3-M |
---|---|---|---|---|---|---|
DC insulation measurement | Yes | |||||
Overload behaviour | Operating point shift. power limitation | |||||
DC disconnector | Yes |
INTERFACES | SYMO 3.0-3-S | SYMO 3.7-3-S | SYMO 4.5-3-S | SYMO 3.0-3-M | SYMO 3.7-3-M | SYMO 4.5-3-M |
---|---|---|---|---|---|---|
WLAN / Ethernet LAN | Fronius Solar.web / Fronius Solar.web, Modbus TCP, JSON | |||||
6 inputs or 4 digital in/out | Interface to ripple control receiver | |||||
USB (A socket)2) | For USB sticks | |||||
2x RS422 (RJ45 socket)2) | Fronius Solar Net. interface protocol | |||||
Signalling output2) | Energy management (potential-free relay output) | |||||
Datalogger and Webserver | Included | |||||
External input | S0-Meter Interface / Input for overvoltage protection |
2) also available in the light version
TECHNICAL DATA FRONIUS SYMO (5.0-3-M, 6.0-3-M, 7.0-3-M, 8.2-3-M)
INPUT DATA | SYMO 5.0-3-M | SYMO 6.0-3-M | SYMO 7.0-3-M | SYMO 8.2-3-M |
---|---|---|---|---|
Max. input current (Idc max 1 / Idc max 2) | 16.0 A / 16.0 A | |||
Max. array short circuit current (MPP1/MPP2) | 24.0 A / 24.0 A | |||
Min. input voltage (Udc min) | 150 V | |||
Feed-in start voltage (Udc start) | 200 V | |||
Nominal input voltage (Udc,r) | 595 V | |||
Max. input voltage (Udc max) | 1,000 V | |||
MPP voltage range (Umpp min – Umpp max) | 163 – 800 V | 195 – 800 V | 228 – 800 V | 267 – 800 V |
Number MPP trackers | 2 | |||
Number of DC connections | 2 + 2 |
OUTPUT DATA | SYMO 5.0-3-M | SYMO 6.0-3-M | SYMO 7.0-3-M | SYMO 8.2-3-M |
---|---|---|---|---|
AC nominal output (Pac,r) | 5,000 W | 6,000 W | 7,000 W | 8,200 W |
Max. output power | 5,000 VA | 6,000 VA | 7,000 VA | 8,200 VA |
Max. output current (Iac max) | 13.5 A | |||
Grid connection (Uac,r) | 3-NPE 400 V / 230 V or 3~NPE 380 V / 220 V | |||
Min. output voltage (Uac min) | 260 / 150 V | |||
Max. output voltage (Uac max) | 485 / 280 V | |||
Frequency (fr) | 50 Hz / 60 Hz | |||
Frequency range (fmin – fmax) | 45 – 65 Hz | |||
Total harmonic distortion | < 3 % | |||
Power factor (cos φac,r) | 0.85 – 1 ind. / cap. |
GENERAL DATA | SYMO 5.0-3-M | SYMO 6.0-3-M | SYMO 7.0-3-M | SYMO 8.2-3-M |
---|---|---|---|---|
Dimensions (height x width x depth) | 645 x 431 x 204 mm | |||
Weight | 19.9 kg | 21.9 kg | ||
Degree of protection | IP 55 | |||
Protection class | 1 | |||
Overvoltage category (DC / AC) 1) | 2 / 3 | |||
Night time consumption | < 1 W | |||
Inverter design | Transformerless | |||
Cooling | Regulated air cooling | |||
Installation | Indoor and outdoor installation | |||
Ambient temperature range | -25 – +60 °C | |||
Permitted humidity | 0 – 100 % | |||
DC connection technology | 4x DC+ and 4x DC- Screw terminals 2.5 – 16mm2 2) | |||
Mains connection technology | 5-pole AC Screw terminals 2.5 – 16mm2 2) | |||
Certificates and compliance with standards | DIN V VDE 0126-1-1/A1, VDE AR N 4105, IEC 62109-1/-2, IEC 62116, IEC 61727, AS 3100, AS 4777-2, AS 4777-3, CER 06-190, G83/2, UNE 206007-1, SI 4777, CEI 0-21 |
1) according to IEC 62109-1.
2) 16 mm2 without wire end ferrules[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]
FRONIUS SYMO 8.2-3-M EFFICIENCY CURVE
[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]
FRONIUS SYMO 8.2-3-M TEMPERATURE DERATING
[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
GENERAL DATA | SYMO 5.0-3-M | SYMO 6.0-3-M | SYMO 7.0-3-M | SYMO 8.2-3-M |
---|---|---|---|---|
Max. efficiency | 98.0 % | |||
European efficiency (ηEU) | 97.0 % | 97.2 % | 97.3 % | 97.5 % |
η at 5 % Pac,r 1) | 84.9 / 91.2 / 85.9 % | 87.8 / 92.6 / 87.8 % | 88.7 / 93.1 / 89.0 % | 89.8 / 93.8 / 90.6 % |
η at 10 % Pac,r 1) | 89.9 / 94.6 / 91.7 % | 91.3 / 95.6 / 93.0 % | 92.0 / 95.9 / 94.7 % | 92.8 / 96.1 / 94.5 % |
η at 20 % Pac,r 1) | 93.2 / 96.7 / 95.4 % | 94.1 / 97.1 / 95.9 % | 94.5 / 97.3 / 96.3 % | 95.0 / 97.6 / 96.6 % |
η at 25 % Pac,r 1) | 93.9 / 97.2 / 96.0 % | 94.7 / 97.5 / 96.5 % | 95.1 / 97.6 / 96.7 % | 95.5 / 97.7 / 97.0 % |
η at 30 % Pac, 1) | 94.5 / 97.4 / 96.5 % | 95.1 / 97.7 / 96.8 % | 95.4 / 97.7 / 97.0 % | 95.8 / 97.8 / 97.2 % |
η at 50 % Pac,r 1) | 95.2 / 97.9 / 97.3 % | 95.7 / 98.0 / 97.5 % | 95.9 / 98.0 / 97.5 % | 96.2 / 98.0 / 97.6 % |
η at 75 % Pac,r 1) | 95.3 / 98.0 / 97.5 % | 95.7 / 98.0 / 97.6 % | 95.9 / 98.0 / 97.6 % | 96.2 / 98.0 / 97.6 % |
η at 100 % Pac,r 1) | 95.2 / 98.0 / 97.6 % | 95.7 / 97.9 / 97.6 % | 95.8 / 97.9 / 97.5 % | 96.0 / 97.8 / 97.5 % |
MPP adaptation efficiency | > 99.9 % |
1) and at Umpp min / Udc,r / Umpp max
GENERAL DATA | SYMO 5.0-3-M | SYMO 6.0-3-M | SYMO 7.0-3-M | SYMO 8.2-3-M |
---|---|---|---|---|
DC insulation measurement | Yes | |||
Overload behaviour | Operating point shift. power limitation | |||
DC disconnector | Yes |
GENERAL DATA | SYMO 5.0-3-M | SYMO 6.0-3-M | SYMO 7.0-3-M | SYMO 8.2-3-M |
---|---|---|---|---|
WLAN / Ethernet LAN | Fronius Solar.web / Fronius Solar.web, Modbus TCP, JSON | |||
6 inputs or 4 digital in/out | Interface to ripple control receiver | |||
USB (A socket)2) | For USB-Sticks | |||
2x RS422 (RJ45 socket)2) | Fronius Solar Net, Interface Protokoll | |||
Signalling output2) | Energy management (potential-free relay output) | |||
Datalogger and Webserver | Included | |||
External input | S0-Meter Interface / Input for overvoltage protection |