[vc_row][vc_column width=”2/3″][vc_column_text]
Fronius IG
Inverters
Updated design for Australian conditions.
With the Fronius IG product family, Fronius has launched a generation of inverters that is compatible with all solar modules. What makes them so appealing is their intuitive operation, ease of use and the sophisticated self-diagnostic system. This makes the Fronius IG a PV inverter that any system operator would welcome.[/vc_column_text][vc_row_inner][vc_column_inner width=”1/1″][vc_column_text]
Technical Data
Input Data | IG 15 | IG 20 | IG 30 | IG 40 | IG 501) | IG 60 HV |
---|---|---|---|---|---|---|
DC maximum power at cos φ = 1 | 1,610 W | 2,150 W | 2,850 W | 4,410 W | 4,950 W | 5,380 W |
Max. input current (Idc max) | 10.8 A | 14.3 A | 19.0 A | 29.4 A | 33.0 A | 35.8 A |
Min. input voltage (U dc min) | 150 V | |||||
Feed-in start voltage (Udc start) | 170 V | |||||
Nominal input voltage (U dc,r) | 280 V | |||||
Max. input voltage (Udc max ) | 500 V | 530 V | ||||
MPP voltage range (Umpp min – Umpp max) | 150 V – 400 V | |||||
Number of DC inputs | 5 |
Output Data | IG 15 | IG 20 | IG 30 | IG 40 | IG 501) | IG 60 HV |
---|---|---|---|---|---|---|
AC nominal output (P ac,r) | 1,300 W | 1,800 W | 2,500 W | 3,500 W | 4,600 W | 4,600 W |
Max. output power | 1,300 W | 2,000 W | 2,650 W | 4,100 W | 4,600 W | 5,000 W |
Max. output current (Iac max) | 6.5 A | 8.7 A | 11.5 A | 17.8 A | 20.0 A | 21.7 A |
Grid connection (Uac,r) | 1~NPE 230 V | |||||
Min. output voltage (Uac min) | 180 V | |||||
Max. output voltage (Uac max ) | 270 V | |||||
Frequency (fr) | 50 Hz / 60 Hz | |||||
Frequency range (fmin – fmax) | 47 Hz – 65 Hz | |||||
Distortion factor | <3 % | |||||
Power factor (cos φac,r) | 1 |
[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][vc_column width=”1/3″][contact-form-7 id=”2456″][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
General Data | IG 15 | IG 20 | IG 30 | IG 40 | IG 501) | IG 60 HV |
---|---|---|---|---|---|---|
Dimensions (height x width x depth) | 366 x 344 x 220 mm / 500 x 435 x 225 mm2) | 610 x 344 x 220 mm / 733 x 435 x225 mm2) | ||||
Weight | 9 kg / 12 kg2) | 16 kg / 20 kg2) | ||||
Degree of protection | IP 21 / IP 452) | |||||
Protection class | 1 | |||||
Overvoltage category (DC / AC) | 2 / 3 | |||||
Night-time consumption | < 1 W | |||||
Inverter concept | HF transformer | |||||
Cooling | Regulated air cooling | |||||
Installation | Indoor and outdoor installation2) | |||||
Ambient temperature range | from -20°C – +50°C | |||||
Permitted humidity | 0% – 95% | |||||
DC connection technology | Screw terminal connection 1.5 – 10 mm2; DC plug optional3) | |||||
AC connection technology | Screw terminal connection 1.5 – 16 mm2 | |||||
Certificates and compliance with standards | DIN V VDE V 0126-1-1, ÖVE/ÖNORM E 8001-4-712, UTE C15-712-1, EN 50438, G83, G59, C 10 / 11, CER 06-190, Guide for connections to ENEL Distribution electricity network, AS 4777-1, AS 4777-2, AS 4777-3 |
1) Fronius IG 50 devices may only be used in Germany. 2) This applies to Fronius IG Outdoor 3) MC3, MC4 or Tyco[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]
Fronius IG 60 HV Efficiency Curve
[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]
Fronius IG Temperature Derating
[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
Technical Data
Efficiency | IG 15 | IG 20 | IG 30 | IG 40 | IG 501) | IG 60 HV |
---|---|---|---|---|---|---|
Max. efficiency | 94.2 % | 94.3 % | 94.3 % | 94.3 % | 94.3 % | 94.3 % |
European efficiency (ηEU) | 91.4 % | 92.3 % | 92.9 % | 93.2 % | 93.5 % | 93.5 % |
η at 5% Pac,r4) | 75.0 / 76.9 / 71.1 % | 77.4 / 80.6 / 71.1 % | 81.6 / 83.1 / 81.4 % | 82.7 / 83.3 / 80.2 % | 85.6 / 85.8 / 83.3 % | 85.6 / 85.8 / 83.3 % |
η at 10% Pac,r4) | 81.6 / 83.1 / 81.4 % | 84.9 / 86.2 / 83.4 % | 87.4 / 88.6 / 85.9 % | 88.5 / 89.3 / 85.0 % | 90.0 / 90.3 / 87.5 % | 90.0 / 90.3 / 87.5 % |
η at 20% P ac,r4) | 87.8 / 89.2 / 85.9 % | 89.7 / 90.5 / 87.3 % | 91.2 / 91.8 / 89.1 % | 91.5 / 92.3 / 89.6 % | 92.2 / 93.0 / 90.8 % | 92.2 / 93.0 / 90.8 % |
η at 25% Pac,r4) | 89.3 / 89.9 / 86.8 % | 90.8 / 91.3 / 88.5 % | 91.8 / 92.7 / 90.2 % | 92.1 / 92.9 / 90.6 % | 92.4 / 93.5 / 91.6 % | 92.4 / 93.5 / 91.6 % |
η at 30% P ac,r4) | 90.1 / 90.7 / 87.9 % | 91.5 / 92.3 / 89.8 % | 92.3 / 93.2 / 90.9 % | 92.4 / 93.3 / 91.1 % | 92.5 / 93.6 / 92.1 % | 92.5 / 93.6 / 92.1 % |
η at 50% P ac,r4) | 92.0 / 92.9 / 90.3 % | 92.6 / 93.7 / 91.4 % | 92.8 / 94.0 / 92.4 % | 92.7 / 93.9 / 91.5 % | 92.9 / 94.3 / 92.3 % | 92.9 / 94.3 / 92.3 % |
η at 75% Pac,r4) | 92.7 / 93.8 / 91.7 % | 92.8 / 94.3 / 92.6 % | 92.4 / 94.3 / 92.8 % | 92.9 / 94.1 / 92.6 % | 92.5 / 94.1 / 92.9 % | 92.5 / 94.1 / 92.9 % |
η at 100% Pac,r4) | 92.8 / 94.2 / 92.5 % | 92.4 / 94.0 / 92.9 % | 92.0 / 93.4 / 92.6 % | 92.5 / 94.3 / 92.9 % | 92.0 / 93.7 / 92.7 % | 92.0 / 93.7 / 92.7 % |
MPP adaptation efficiency | > 99.9 % |
4) and at Umpp min / Udc,r / Umpp max[/vc_column_text][vc_column_text]
Protective Equipment | IG 15 | IG 20 | IG 30 | IG 40 | IG 501) | IG 60 HV |
---|---|---|---|---|---|---|
DC insulation measurement | Warning/shutdown (depending on country setup) at RISO < 500 kOhm | |||||
Overload behaviour | Operating point shift, power limitation | |||||
Reverse polarity protection | Integrated |
[/vc_column_text][/vc_column][/vc_row]