[vc_row][vc_column width=”2/3″][vc_column_text]

SolarEdge Three Phase Inverterssolaredge three phase

The SolarEdge Three Phase Inverter combines sophisticated digital control technology with efficient power conversion architecture to achieve superior solar power harvesting and best-in-class reliability.
The fixed-voltage technology ensures the solar inverter is always working at its optimal input voltage, regardless of the number of modules in a string or environmental conditions.
A proprietary data monitoring receiver has been integrated into the inverter and aggregates the power optimizer performance data from each PV module. This data can be transmitted to the web and accessed via the SolarEdge Monitoring Portal for performance analysis, fault detection and troubleshooting of PV systems.

SolarEdge Three Phase Inverter Feature highlights:

  • Inverters specifically designed to work with power optimizers
  • Superior efficiency (>97%)
  • Excellent reliability with standard 12 year warranty (extendable to 20 or 25 years)
  • Small, lightweight and easy to install
  • Built-in module-level monitoring receiver
  • Communication to internet via broadband or wireless ZigBee
  • IP65 / NEMA 3R – Outdoor and indoor installation

[/vc_column_text][/vc_column][vc_column width=”1/3″][contact-form-7 id=”2456″][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]

SE5k-AUS SE7k-AUS SE8k-AUS SE9k-AUS SE10k-AUS SE12.5k-AUS SE15k-AUS SE16k-AUS SE17k-AUS
OUTPUT
Rated AC Power Output 4985 7000 8000 9000 10000 12500 15000 16000 17000 VA
Maximum AC Power Output 4985 7000 8000 9000 10000 12500 15000 16000 17000 VA
AC Output Voltage – Line to Line / Line to Neutral (Nominal) 400 / 230 Vac
AC Output Voltage – Line to Neutral Range 184 – 264.5 Vac
AC Frequency 50 ± 5 Hz
Maximum Continuous Output Current (per Phase) 8 11.5 13 14.5 16 20 23 25.5 26 A
Residual Current Detector / Residual Current Step Detector 300 / 30 mA
Grids Supported – 3-Phase 3 / N / PE ; 230 / 400 V
Utility Monitoring, Islanding Protection, Configurable, Power Factor, Country, Configurable Thresholds Yes
INPUT
Recommended Maximum DC Power* (Module STC) 5500 7700 8800 9900 11000 13700 16500 17600 18700 W
Transformer-less, Ungrounded Yes
Nominal DC Input Voltage DC to Gnd 375 Vdc
Maximum Input Voltage DC to Gnd 415 Vdc
Nominal DC Input Voltage DC+ to DC- 750 Vdc
Maximum Input Voltage DC+ to DC- 830 Vdc
Maximum Input Current 8.5 12 13.5 15 16.5 21 22 23 23 Vdc
Reverse-Polarity Protection Yes
Ground-Fault Isolation Detection 1MΩ Sensitivity
Maximum Inverter Efficiency 98 %
European Weighted Efficiency 97.3 97.3 97.5 97.5 97.6 97.7 97.6 97.7 97.7 %
Nighttime Power Consumption < 2.5 W
ADDITIONAL FEATURES
Supported Communication Interfaces RS485, RS232, Ethernet, Zigbee (optional)
STANDARD COMPLIANCE
Safety IEC-62103 (EN50178), IEC-62109
Grid Connection Standards VDE 0126-1-1, VDE-AR-N-4105, AS-4777, RD-1663 , DK 5940
Emissions IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part15 class B
RoHS Yes
INSTALLATION SPECIFICATIONS
AC Output Cable Gland – diameter 15-21 mm
DC Input 2 MC4 pairs
Dimensions (HxWxD) 540 x 315 x 260 mm
Weight 33.2 kg
Operating Temperature Range -20 – +60 (M40 version -40 – +60) ̊C
Cooling Fan (user replaceable)
Noise < 50 dBA
Protection Rating IP65 – Outdoor and Indoor
Bracket Mounted (Bracket Provided)

* Higher input DC power may be installed; analyze yearly AC performance.[/vc_column_text][/vc_column][/vc_row]