[vc_row][vc_column width=”2/3″][vc_column_text]

SolarEdge Single Phase Inverterssolaredge single phase

The SolarEdge Single Plase Inverter combines sophisticated digital control technology with efficient power conversion architecture to achieve superior solar power harvesting and best-in-class reliability.
The fixed-voltage technology ensures the solar inverter is always working at its optimal input voltage, regardless of the number of modules in a string or environmental conditions.
A proprietary data monitoring receiver has been integrated into the single phase solar inverter and aggregates the power optimizer performance data from each PV module. This data can be transmitted to the web and accessed via the SolarEdge monitoring portal for performance analysis, fault detection and troubleshooting of SolarEdge PV Systems.
The single phase inverter can be fitted with a seamlessly attachable cabling duct for managing the installation wiring. The inverters are lightweight and can be installed by a single person on a supplied bracket.

SolarEdge Single Phase Inverter Feature highlights:

  • Solar inverters specifically designed to work with power optimizers
  • Superior efficiency (>97%)
  • Excellent reliability with standard 12 year warranty (extendable to 20 or 25 years)
  • Small, lightweight and easy to install
  • Built-in module-level monitoring receiver
  • Communication to internet via broadband or wireless ZigBee
  • IP65 / NEMA 3R – Outdoor and indoor installation

[/vc_column_text][/vc_column][vc_column width=”1/3″][contact-form-7 id=”2456″][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]

SE2200-AUS SE3000-AUS SE3500-AUS SE4000-AUS SE4600-AUS SE5000-AUS SE6000-AUS
OUTPUT
Rated AC Power Output 2200 3000 3500 4000 4600 4985 6000 VA
Maximum AC Power Output 2200 3000 3500 4000 4600 4985 6000 VA
AC Output Voltage (Nominal) 220 /230 Vac
AC Output Voltage Range 184 – 264.5 Vac
AC Frequency (Nominal) 50 / 60 ± 5 Hz
Maximum Continuous Output Current 12 16.5 19.5 22 25 27 27 A
Residual Current Detector / Residual Current Step Detector 300 / 30 mA
Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes
INPUT
Recommended Maximum DC Power* (Module STC) 2400 3300 3900 4400 5100 5500 6600 W
Transformer-less, Ungrounded Yes
Maximum Input Voltage 500 Vdc
Nominal DC Input Voltage 350 Vdc
Maximum Input Current 8.5 11.5 13.5 15.5 17.5 19.5 23 Adc
Reverse-Polarity Protection Yes
Ground-Fault Isolation Detection 600kΩ Sensitivity
Maximum Inverter Efficiency 97.6 %
European Weighted Efficiency 97.6 97.6 97.5 97.5 97.4 97.4 97.4 %
Nighttime Power Consumption < 2.5 W
ADDITIONAL FEATURES
Supported Communication Interfaces RS485, RS232, Ethernet, Zigbee (optional)
STANDARD COMPLIANCE
Safety IEC-62103 (EN50178), IEC-62109
Grid Connection Standards VDE 0126-1-1, VDE-AR-N-4105, AS-4777, RD-1663 , DK 5940
Emissions IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part15 class B
RoHS Yes
INSTALLATION SPECIFICATIONS
AC Output Cable Gland – diameter 9-16 mm
DC Input 1 MC4 pair 2 MC4 pairs
Dimensions (HxWxD) 540 x 315 x 172 540 x 315 x 191 mm
Weight 20.2 21.7 kg
Cooling Natural Convection
Noise < 50 dBA
Operating Temperature Range -20 – +50 (M40 version -40 – +50) ̊C
Protection Rating IP65 – Outdoor and Indoor
Bracket Mounted (Bracket Provided)