[vc_row][vc_column width=”2/3″][vc_column_text]

SMA Sunny Tripower TL 5000-9000 Inverterssma sunny tripower tl 9000

The Sunny Tripower PV plant with 5 to 9 kW of power is setting new standards in three-phase systems. It features an asymmetric multi-string and Optiflex technology to ensure the highest in flexibility while combining peak efficiency with the OptiTrac Global Peak system to generate the highest in yields. In addition to communication via the external Bluetooth-antenna, the PV plant comes with a direct Sunny Portal connection via SMA Webconnect as standard – and now for the first time without data loggers. The “small” Sunny Tripower also comes with integrated grid management functions and reactive power supply.

Economical

  • Maximum efficiency of 98 %
  • Shade management with OptiTrac Global Peak
  • Active temperature management with OptiCool

Flexible

  • DC input voltage of up to 1,000 V
  • Integrated grid management functions
  • Reactive power supply
  • Module-tailored plant design with Optiflex

Communicative

  • SMA Webconnect Portal communication
  • Bluetooth® communication
  • Simple country configuration
  • Multi-function relay as standard

Simple

  • Three-phase feed-in
  • Cable connection without tools
  • SUNCLIX DC plug-in system
  • Integrated ESS DC switch-disconnector
  • Easy wall mounting

[/vc_column_text][/vc_column][vc_column width=”1/3″][contact-form-7 id=”2456″][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]

Technical Data

Sunny Tripower
5000TL
Sunny Tripower
6000TL
Sunny Tripower
7000TL
Sunny Tripower
8000TL
Sunny Tripower
9000TL
Input (DC)
Max. DC power (@ cos φ=1) 5100 W 6125 W 7175 W 8200 W 9225 W
Max. input voltage 1000 V 1000 V 1000 V 1000 V 1000 V
MPP voltage range / rated input voltage 245 V … 800 V / 580 V 295 V … 800 V / 580 V 290 V … 800 V / 580 V 330 V … 800 V / 580 V 370 V … 800 V / 580 V
Min. input voltage / initial input voltage 150 V / 188 V 150 V / 188 V 150 V / 188 V 150 V / 188 V 150 V / 188 V
Max. input current input A / input B 11 A / 10 A 11 A / 10 A 15 A / 10 A 15 A / 10 A 15 A / 10 A
Max. input current per string input A / input B 11 A / 10 A 11 A / 10 A 15 A / 10 A 15 A / 10 A 15 A / 10 A
Number of independent MPP inputs / strings per MPP input 2 / A:2; B:2 2 / A:2; B:2 2 / A:2; B:2 2 / A:2; B:2 2 / A:2; B:2
Output (AC)
Rated power (@ 230 V, 50 Hz) 5000 W 6000 W 7000 W 8000 W 9000 W
Max. apparent AC power 5000 VA 6000 VA 7000 VA 8000 VA 9000 VA
AC nominal voltage 3 / N / PE; 220 / 380 V
3 / N / PE; 230 / 400 V
3 / N / PE; 240 / 415 V
3 / N / PE; 220 / 380 V
3 / N / PE; 230 / 400 V
3 / N / PE; 240 / 415 V
3 / N / PE; 220 / 380 V
3 / N / PE; 230 / 400 V
3 / N / PE; 240 / 415 V
3 / N / PE; 220 / 380 V
3 / N / PE; 230 / 400 V
3 / N / PE; 240 / 415 V
3 / N / PE; 220 / 380 V
3 / N / PE; 230 / 400 V
3 / N / PE; 240 / 415 V
Nominal AC voltage range 160 V – 280 V 160 V – 280 V 160 V – 280 V 160 V – 280 V 160 V – 280 V
AC power frequency / range 50 Hz, 60 Hz / -5 Hz … +5 Hz 50 Hz, 60 Hz / -5 Hz … +5 Hz 50 Hz, 60 Hz / -5 Hz … +5 Hz 50 Hz, 60 Hz / -5 Hz … +5 Hz 50 Hz, 60 Hz / -5 Hz … +5 Hz
Rated power frequency / rated grid voltage 50 Hz / 230 V 50 Hz / 230 V 50 Hz / 230 V 50 Hz / 230 V 50 Hz / 230 V
Max. output current 7.3 A 8.7 A 10.2 A 11.6 A 13.1 A
Power factor at rated power 1 1 1 1 1
Adjustable displacement power factor 0.8 overexcited … 0.8 underexcited 0.8 overexcited … 0.8 underexcited 0.8 overexcited … 0.8 underexcited 0.8 overexcited … 0.8 underexcited 0.8 overexcited … 0.8 underexcited
Feed-in phases / connection phases 3 / 3 3 / 3 3 / 3 3 / 3 3 / 3
Efficiency
Max. efficiency / European efficiency 98 % / 97.1 % 98.1 % / 97.4 % 98 % / 97.5 % 98 % / 97.6 % 98 % / 97.6 %
Protective devices
DC disconnect device yes yes yes yes yes
Ground fault monitoring / grid monitoring yes / yes yes / yes yes / yes yes / yes yes / yes
DC reverse polarity protection / AC short-circuit current capability / galvanically isolated yes / yes / — yes / yes / — yes / yes / — yes / yes / — yes / yes / —
All-pole-sensitive residual-current monitoring unit yes yes yes yes yes
Protection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1) I / III I / III I / III I / III I / III
General Data
Dimensions (W / H / D) 470 / 730 / 240 mm
(18.5 / 28.7 / 9.5 inches)
470 / 730 / 240 mm
(18.5 / 28.7 / 9.5 inches)
470 / 730 / 240 mm
(18.5 / 28.7 / 9.5 inches)
470 / 730 / 240 mm
(18.5 / 28.7 / 9.5 inches)
470 / 730 / 240 mm
(18.5 / 28.7 / 9.5 inches)
Weight 37 kg / 81.6 lb 37 kg / 81.6 lb 37 kg / 81.6 lb 37 kg / 81.6 lb 37 kg / 81.6 lb
Operating temperature range -25 °C … +60 °C /
-13 °F … +140 °F
-25 °C … +60 °C /
-13 °F … +140 °F
-25 °C … +60 °C /
-13 °F … +140 °F
-25 °C … +60 °C /
-13 °F … +140 °F
-25 °C … +60 °C /
-13 °F … +140 °F
Noise emission (typical) 40 dB(A) 40 dB(A) 40 dB(A) 40 dB(A) 40 dB(A)
Self-consumption (night) 1 W 1 W 1 W 1 W 1 W
Topology / cooling concept Transformerless / OptiCool Transformerless / OptiCool Transformerless / OptiCool Transformerless / OptiCool Transformerless / OptiCool
Degree of protection (according to IEC 60529) IP65 IP65 IP65 IP65 IP65
Climatic category (according to IEC 60721-3-4) 4K4H 4K4H 4K4H 4K4H 4K4H
Maximum permissible value for relative humidity (non-condensing) 100 % 100 % 100 % 100 % 100 %
Features
DC connection / AC connection SUNCLIX / Spring clamp terminal SUNCLIX / Spring clamp terminal SUNCLIX / Spring clamp terminal SUNCLIX / Spring clamp terminal SUNCLIX / Spring clamp terminal
Display Graphic Graphic Graphic Graphic Graphic
Interface: RS485 / Bluetooth / Webconnect – / yes / yes – / yes / yes – / yes / yes – / yes / yes – / yes / yes
Multi-function relay / Power Control Module yes / opt. yes / opt. yes / opt. yes / opt. yes / opt.
Warranty: 5 / 10 / 15 / 20 / 25 years yes / opt. / opt. / opt. / opt. yes / opt. / opt. / opt. / opt. yes / opt. / opt. / opt. / opt. yes / opt. / opt. / opt. / opt. yes / opt. / opt. / opt. / opt.
Certificates and approvals (additional on request) CE, VDE0126-1-1, UTE C15-712-1, VDE-AR-N 4105 CE, VDE0126-1-1, UTE C15-712-1, VDE-AR-N 4105 VDE0126-1-1, UTE C15-712-1, VDE-AR-N 4105 VDE0126-1-1, UTE C15-712-1, VDE-AR-N 4105 VDE0126-1-1, UTE C15-712-1, VDE-AR-N 4105
Certificates and approvals (planned) RD 661/2007, PPC, AS 4777, EN 50438*, C10/11, PPDS, IEC 61727, SI4777, G83/1-1 , CEI 0-21, RD1699 RD 661/2007, PPC, AS 4777, EN 50438*, C10/11, PPDS, IEC 61727, SI4777, G83/1-1 , CEI 0-21, RD1699 RD 661/2007, PPC, AS 4777, EN 50438*, C10/11, PPDS, IEC 61727, SI4777, G83/1-1 , CEI 0-21, RD1699 RD 661/2007, PPC, AS 4777, EN 50438*, C10/11, PPDS, IEC 61727, SI4777, G83/1-1 , CEI 0-21, RD1699 RD 661/2007, PPC, AS 4777, EN 50438*, C10/11, PPDS, IEC 61727, SI4777, G83/1-1 , CEI 0-21, RD1699
Type designation STP 5000TL-20 STP 6000TL-20 STP 7000TL-20 STP 8000TL-20 STP 9000TL-20

* Does not apply to all national appendices of EN 50438
Preliminary information – last updated: August 2012
Data at nominal conditions[/vc_column_text][/vc_column][/vc_row]