[vc_row][vc_column width=”2/3″][vc_column_text]
SMA Sunny Tripower TL 5000-9000 Inverters
The Sunny Tripower PV plant with 5 to 9 kW of power is setting new standards in three-phase systems. It features an asymmetric multi-string and Optiflex technology to ensure the highest in flexibility while combining peak efficiency with the OptiTrac Global Peak system to generate the highest in yields. In addition to communication via the external Bluetooth-antenna, the PV plant comes with a direct Sunny Portal connection via SMA Webconnect as standard – and now for the first time without data loggers. The “small” Sunny Tripower also comes with integrated grid management functions and reactive power supply.
- Maximum efficiency of 98 %
- Shade management with OptiTrac Global Peak
- Active temperature management with OptiCool
Flexible
- DC input voltage of up to 1,000 V
- Integrated grid management functions
- Reactive power supply
- Module-tailored plant design with Optiflex
Communicative
- SMA Webconnect Portal communication
- Bluetooth® communication
- Simple country configuration
- Multi-function relay as standard
Simple
- Three-phase feed-in
- Cable connection without tools
- SUNCLIX DC plug-in system
- Integrated ESS DC switch-disconnector
- Easy wall mounting
[/vc_column_text][/vc_column][vc_column width=”1/3″][contact-form-7 id=”2456″][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
Technical Data
Sunny Tripower 5000TL |
Sunny Tripower 6000TL |
Sunny Tripower 7000TL |
Sunny Tripower 8000TL |
Sunny Tripower 9000TL |
|
---|---|---|---|---|---|
Input (DC) | |||||
Max. DC power (@ cos φ=1) | 5100 W | 6125 W | 7175 W | 8200 W | 9225 W |
Max. input voltage | 1000 V | 1000 V | 1000 V | 1000 V | 1000 V |
MPP voltage range / rated input voltage | 245 V … 800 V / 580 V | 295 V … 800 V / 580 V | 290 V … 800 V / 580 V | 330 V … 800 V / 580 V | 370 V … 800 V / 580 V |
Min. input voltage / initial input voltage | 150 V / 188 V | 150 V / 188 V | 150 V / 188 V | 150 V / 188 V | 150 V / 188 V |
Max. input current input A / input B | 11 A / 10 A | 11 A / 10 A | 15 A / 10 A | 15 A / 10 A | 15 A / 10 A |
Max. input current per string input A / input B | 11 A / 10 A | 11 A / 10 A | 15 A / 10 A | 15 A / 10 A | 15 A / 10 A |
Number of independent MPP inputs / strings per MPP input | 2 / A:2; B:2 | 2 / A:2; B:2 | 2 / A:2; B:2 | 2 / A:2; B:2 | 2 / A:2; B:2 |
Output (AC) | |||||
Rated power (@ 230 V, 50 Hz) | 5000 W | 6000 W | 7000 W | 8000 W | 9000 W |
Max. apparent AC power | 5000 VA | 6000 VA | 7000 VA | 8000 VA | 9000 VA |
AC nominal voltage | 3 / N / PE; 220 / 380 V 3 / N / PE; 230 / 400 V 3 / N / PE; 240 / 415 V |
3 / N / PE; 220 / 380 V 3 / N / PE; 230 / 400 V 3 / N / PE; 240 / 415 V |
3 / N / PE; 220 / 380 V 3 / N / PE; 230 / 400 V 3 / N / PE; 240 / 415 V |
3 / N / PE; 220 / 380 V 3 / N / PE; 230 / 400 V 3 / N / PE; 240 / 415 V |
3 / N / PE; 220 / 380 V 3 / N / PE; 230 / 400 V 3 / N / PE; 240 / 415 V |
Nominal AC voltage range | 160 V – 280 V | 160 V – 280 V | 160 V – 280 V | 160 V – 280 V | 160 V – 280 V |
AC power frequency / range | 50 Hz, 60 Hz / -5 Hz … +5 Hz | 50 Hz, 60 Hz / -5 Hz … +5 Hz | 50 Hz, 60 Hz / -5 Hz … +5 Hz | 50 Hz, 60 Hz / -5 Hz … +5 Hz | 50 Hz, 60 Hz / -5 Hz … +5 Hz |
Rated power frequency / rated grid voltage | 50 Hz / 230 V | 50 Hz / 230 V | 50 Hz / 230 V | 50 Hz / 230 V | 50 Hz / 230 V |
Max. output current | 7.3 A | 8.7 A | 10.2 A | 11.6 A | 13.1 A |
Power factor at rated power | 1 | 1 | 1 | 1 | 1 |
Adjustable displacement power factor | 0.8 overexcited … 0.8 underexcited | 0.8 overexcited … 0.8 underexcited | 0.8 overexcited … 0.8 underexcited | 0.8 overexcited … 0.8 underexcited | 0.8 overexcited … 0.8 underexcited |
Feed-in phases / connection phases | 3 / 3 | 3 / 3 | 3 / 3 | 3 / 3 | 3 / 3 |
Efficiency | |||||
Max. efficiency / European efficiency | 98 % / 97.1 % | 98.1 % / 97.4 % | 98 % / 97.5 % | 98 % / 97.6 % | 98 % / 97.6 % |
Protective devices | |||||
DC disconnect device | yes | yes | yes | yes | yes |
Ground fault monitoring / grid monitoring | yes / yes | yes / yes | yes / yes | yes / yes | yes / yes |
DC reverse polarity protection / AC short-circuit current capability / galvanically isolated | yes / yes / — | yes / yes / — | yes / yes / — | yes / yes / — | yes / yes / — |
All-pole-sensitive residual-current monitoring unit | yes | yes | yes | yes | yes |
Protection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1) | I / III | I / III | I / III | I / III | I / III |
General Data | |||||
Dimensions (W / H / D) | 470 / 730 / 240 mm (18.5 / 28.7 / 9.5 inches) |
470 / 730 / 240 mm (18.5 / 28.7 / 9.5 inches) |
470 / 730 / 240 mm (18.5 / 28.7 / 9.5 inches) |
470 / 730 / 240 mm (18.5 / 28.7 / 9.5 inches) |
470 / 730 / 240 mm (18.5 / 28.7 / 9.5 inches) |
Weight | 37 kg / 81.6 lb | 37 kg / 81.6 lb | 37 kg / 81.6 lb | 37 kg / 81.6 lb | 37 kg / 81.6 lb |
Operating temperature range | -25 °C … +60 °C / -13 °F … +140 °F |
-25 °C … +60 °C / -13 °F … +140 °F |
-25 °C … +60 °C / -13 °F … +140 °F |
-25 °C … +60 °C / -13 °F … +140 °F |
-25 °C … +60 °C / -13 °F … +140 °F |
Noise emission (typical) | 40 dB(A) | 40 dB(A) | 40 dB(A) | 40 dB(A) | 40 dB(A) |
Self-consumption (night) | 1 W | 1 W | 1 W | 1 W | 1 W |
Topology / cooling concept | Transformerless / OptiCool | Transformerless / OptiCool | Transformerless / OptiCool | Transformerless / OptiCool | Transformerless / OptiCool |
Degree of protection (according to IEC 60529) | IP65 | IP65 | IP65 | IP65 | IP65 |
Climatic category (according to IEC 60721-3-4) | 4K4H | 4K4H | 4K4H | 4K4H | 4K4H |
Maximum permissible value for relative humidity (non-condensing) | 100 % | 100 % | 100 % | 100 % | 100 % |
Features | |||||
DC connection / AC connection | SUNCLIX / Spring clamp terminal | SUNCLIX / Spring clamp terminal | SUNCLIX / Spring clamp terminal | SUNCLIX / Spring clamp terminal | SUNCLIX / Spring clamp terminal |
Display | Graphic | Graphic | Graphic | Graphic | Graphic |
Interface: RS485 / Bluetooth / Webconnect | – / yes / yes | – / yes / yes | – / yes / yes | – / yes / yes | – / yes / yes |
Multi-function relay / Power Control Module | yes / opt. | yes / opt. | yes / opt. | yes / opt. | yes / opt. |
Warranty: 5 / 10 / 15 / 20 / 25 years | yes / opt. / opt. / opt. / opt. | yes / opt. / opt. / opt. / opt. | yes / opt. / opt. / opt. / opt. | yes / opt. / opt. / opt. / opt. | yes / opt. / opt. / opt. / opt. |
Certificates and approvals (additional on request) | CE, VDE0126-1-1, UTE C15-712-1, VDE-AR-N 4105 | CE, VDE0126-1-1, UTE C15-712-1, VDE-AR-N 4105 | VDE0126-1-1, UTE C15-712-1, VDE-AR-N 4105 | VDE0126-1-1, UTE C15-712-1, VDE-AR-N 4105 | VDE0126-1-1, UTE C15-712-1, VDE-AR-N 4105 |
Certificates and approvals (planned) | RD 661/2007, PPC, AS 4777, EN 50438*, C10/11, PPDS, IEC 61727, SI4777, G83/1-1 , CEI 0-21, RD1699 | RD 661/2007, PPC, AS 4777, EN 50438*, C10/11, PPDS, IEC 61727, SI4777, G83/1-1 , CEI 0-21, RD1699 | RD 661/2007, PPC, AS 4777, EN 50438*, C10/11, PPDS, IEC 61727, SI4777, G83/1-1 , CEI 0-21, RD1699 | RD 661/2007, PPC, AS 4777, EN 50438*, C10/11, PPDS, IEC 61727, SI4777, G83/1-1 , CEI 0-21, RD1699 | RD 661/2007, PPC, AS 4777, EN 50438*, C10/11, PPDS, IEC 61727, SI4777, G83/1-1 , CEI 0-21, RD1699 |
Type designation | STP 5000TL-20 | STP 6000TL-20 | STP 7000TL-20 | STP 8000TL-20 | STP 9000TL-20 |
* Does not apply to all national appendices of EN 50438
Preliminary information – last updated: August 2012