[vc_row][vc_column width=”2/3″][vc_column_text]

SMA Sunny IslandSMA Sunny Island Inverter

Simple. Robust. Flexible.

More durable than its predecessors: The SMA Sunny Island impresses with its high protection class and wide temperature range. Moisture, dust and temperature fluctuations won’t impair its operation, even after 20 years. Thanks to OptiCool, there’s no need to compromise when it comes to overload capacity and economic viability. And there’s more: OptiPower, the intelligent load and energy management system, ensures operation even in critical situations. OptiUse makes installation, commissioning and daily use easier than ever with automatic rotary field detection, an optimized quick configuration guide and intuitive operation. And the intelligent OptiBat battery management system automatically controls the most important charging and discharging procedures, which extends the service life of sensitive energy storage. Sunny Island is a truly comprehensive package for a worry-free, reliable and self-sufficient electricity supply.

Easy to use

  • OptiUse: fast installation and commissioning, simplified operation
  • OptiBat: state of charge calculation keeps you informed at all times

Robust

  • IP 54: optimal protection from  dust and humidity
  • OptiCool: greater temperature  range
  • OptiPower: secure operation in any situation

Flexible

  • For systems from 3 to 300 kW
  • Precise design
  • Supports Multicluster Technology

 
[/vc_column_text][/vc_column][vc_column width=”1/3″][contact-form-7 id=”2456″][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]sma sunny island wiring diagram 3 phase[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]sma sunny island wiring diagram single phase[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]sma sunny island efficiency curve

Technical data Sunny Island 6.0H Sunny Island 8.0H
AC output (loads / stand-alone grid)
Rated grid voltage / AC voltage range 230 V / 202 V … 253 V 230 V / 202 V … 253 V
Rated frequency / frequency range (adjustable) 50 Hz / 45 Hz … 65 Hz 50 Hz / 45 Hz … 65 Hz
Rated power (for Unom / fnom / 25°C / cos φ = 1) 4600 W 6000 W
AC power at 25°C for 30 min / 5 min / 3 sec 6 000 W / 6 800 W / 11 000 W 8 000 W / 9 100 W / 11 000 W
Rated current / maximum output current (peak) 20 A / 120 A 20 A / 120 A
Total harmonic factor output voltage / power factor with rated power < 4 % / -1 … +1 < 4 % / -1 … +1
AC input (PV array, grid or MC box)
Rated input voltage / AC input voltage range 230 V / 172.5 V … 264.5 V 230 V / 172.5 V … 264.5 V
Rated input frequency / allowable input frequency range 50 Hz / 40 Hz … 70 Hz 50 Hz / 40 Hz … 70 Hz
Maximum AC input current 50 A 50 A
Maximum AC input power 11 500 W 11 500 W
Battery DC input
Rated input voltage / DC voltage range 48 V / 41 V … 63 V 48 V / 41 V … 63 V
Maximum battery charging current 110 A 140 A
Rated DC charging current / DC discharging current 90 A / 103 A 115 A / 136 A
Battery type / battery capacity (range) FLA, VRLA / 100 Ah … 10 000 Ah FLA, VRLA / 100 Ah … 10 000 Ah
Charge control IUoU charge procedure with automatic full charge and equalization charge. IUoU charge procedure with automatic full charge and equalization charge.
Efficiency / self-consumption
Maximum efficiency 95 % 95 %
Self-consumption without load / standby < 26 W / < 4 W < 26 W / < 4 W
Protective devices (equipment)
AC short-circuit / AC overload ♦ / ♦ ♦ / ♦
DC reverse polarity protection / DC fuse – / – – / –
Overtemperature / battery deep discharge ♦ / ♦ ♦ / ♦
Overvoltage category as per IEC 60664-1 III III
General data
Dimensions (width x height x depth) 467 mm x 612 mm x 242 mm 467 mm x 612 mm x 242 mm
Priority 63 kg 63 kg
Operating temperature range -25°C … +60°C -25°C … +60°C
Protection class (according to IEC 62103) I I
Climatic category according to IEC 60721 3K6 3K6
Degree of protection according to IEC 60529 IP 54 IP 54
Features / function
Operation and display / multifunction relay External via SRC-20 / 2 External via SRC-20 / 2
Three-phase systems / parallel connection ♦ / ♦ ♦ / ♦
Integrated bypass / multicluster operation – / ♦ – / ♦
State of charge calculation / full charge / equalization charge ♦ / ♦ / ♦ ♦ / ♦ / ♦
Integrated soft start / generator support ♦ / ♦ ♦ / ♦
Battery temperature sensor / data cables ♦ / ♦ ♦ / ♦
Certificates and approvals www.sma-solar.com www.sma-solar.com
Warranty: 5 years
Accessory
Battery cable / battery fuse ◊ / ◊ ◊ / ◊
Interface SI-COMSMA (RS485) / SI-SYSCAN (Multicluster) ◊ / ◊ ◊ / ◊
Extended generator start “GenMan”
Load-shedding contactor / battery current measurement ◊ / ◊ ◊ / ◊
Type designation SI6.0H-11 SI8.0H-11

♦ Standard features ◊ Optional features – Not available
Data at nominal conditions – provisional data, as of March 2013[/vc_column_text][/vc_column][/vc_row]