[vc_row][vc_column width=”2/3″][vc_column_text]
Schneider Conext XW Range
One solution for global power
Conext XW is an adaptable pure sine wave, single-phase and three-phase inverter/charger system with global grid-tie functionality and dual AC power inputs. Available solar charge controllers, monitoring, and automated generator control modules enable further adaptability. From single Conext XW unit to multiple clusters of units, up to 36 kW each, the Conext XW is a scalable system that allows for the integration of solar capacity as required.
Adaptable and scalable, the Schneider ElectricTM Conext XW system is the one solution for global grid-interactive and off-grid, residential and commercial, solar and backup power applications.[/vc_column_text][vc_column_text]Why choose the Schneider Conext XW Range?
[/vc_column_text][/vc_column][vc_column width=”1/3″][contact-form-7 id=”2456″][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
Product Applications
[/vc_column_text][vc_row_inner][vc_column_inner width=”1/4″][vc_column_text]
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]
[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
Device short name | XW4024 230 50 | XW4548 230 50 | XW6048 230 50 |
---|---|---|---|
Electrical specifications | |||
Output power (continuous) at 40°C | 4.0kVA | 4.5kVA | 6.0kVA |
Output power (surge) at 40°C | 8.0kVA (20 sec) | 9.0kVA (15 sec) | 12.0kVA (15 sec) |
Output current | 17.4A | 19.6A | 26.1A |
Peak output current (rms) | 35A | 40A | 53A |
Input current at rated power | 178A | 96A | 131A |
Type of signal | True sine wave | True sine wave | True sine wave |
Automatic transfer relay | 56A | 56A | 56A |
Typical transfer time | 8ms | 8ms | 8ms |
DC input voltage (nominal) | 25.2V | 50.4V | 50.4V |
Input voltage limits | 20 to 32V | 40 to 64V | 40 to 64V |
Charging current | 150A | 85A | 100A |
Power factor corrected charging | 0.98 | 0.98 | 0.98 |
Auxiliary relay output | 0 to 12V, maximum 250mA DC | 0 to 12V, maximum 250mA DC | 0 to 12V, maximum 250mA DC |
Power consumption (search mode) | < 7W | < 7W | < 7W |
AC input voltage (nominal) | 230V +/- 3% | 230V +/- 3% | 230V +/- 3% |
Input voltage limits (bypass/charge mode) | 165 to 280V (230V nominal) | 165 to 280V (230V nominal) | 165 to 280V (230V nominal) |
Frequency | 50Hz +/- 0.1Hz | 50Hz +/- 0.1Hz | 50Hz +/- 0.1Hz |
AC input frequency range (bypass/charge mode) | 40 to 68Hz (50Hz nominal) | 40 to 68Hz (50Hz nominal) | 40 to 68Hz (50Hz nominal) |
Total harmonic distortion (THD) | < 5% at rated power | < 5% at rated power | < 5% at rated power |
AC connections | AC1 (Grid), AC2 (Generator) | AC1 (Grid), AC2 (Generator) | AC1 (Grid), AC2 (Generator) |
AC input breaker | 60A single-pole | 60A single-pole | 60A single-pole |
Efficiency | |||
Peak | 94.0% | 95.6% | 95.4% |
General specifications | |||
IP degree of protection | IP20 (sensitive electric components sealed inside enclosure) | ||
Product weight | 52.5kg (116.0lb) | 53.5kg (118.0lb) | 55.2kg (121.7lb) |
Shipping weight | 74.0kg (163.0lb) | 75.0kg (165.0lb) | 76.7kg (169.0lb) |
Product dimensions (H x W x D) | 58 x 41 x 23cm (23 x 16 x 9in) | 58 x 41 x 23cm (23 x 16 x 9in) | 58 x 41 x 23cm (23 x 16 x 9in) |
Shipping dimensions (H x W x D) | 71.1 x 57.2 x 39.4cm (28.0 x 22.5 x 15.5in) |
71.1 x 57.2 x 39.4cm (28.0 x 22.5 x 15.5in) |
71.1 x 57.2 x 39.4cm (28.0 x 22.5 x 15.5in) |
Device mounting | Wall mount (backplate included) | Wall mount (backplate included) | Wall mount (backplate included) |
Ambient air temperature for operation | -25°C to 70°C (-13°F to 158°F) (power derated above 45°C (113°F) | ||
System network and remote monitoring | Available | Available | Available |
Warranty | 5 years | 5 years | 5 years |
Part number | 865-1045-61 | 865-1040-61 | 865-1035-61 |
Features and options | |||
Display type | Status LEDs indicate AC In status, faults/warnings, equalise mode, On/Off and equalise button battery level. Three-character display indicates output power or charge current |
||
Supported battery types | Flooded (default), Gel, AGM, custom | Flooded (default), Gel, AGM, custom | Flooded (default), Gel, AGM, custom |
Battery bank size | 100 to 2000Ah (scaled to PV array size) | ||
Battery temperature sensor | Included | Included | |
Non volitaile memory | Yes | Yes | |
Multiple unit configurations | Single-phase: up to four parallel units. Three-phase: two units per phase | ||
Regulatory approval | |||
CE marked according to the following EU directives and standards: | |||
EMC directive | EN61000-6-1, EN61000-6-3, EN61000-3-2, EN61000-3-3 | ||
Low voltage directive | EN50178 | ||
RCM marked and compliant | AS 4777.2, AS 4777.3, AS/NZS 3100 |