[vc_row][vc_column width=”2/3″][vc_column_text]
Schneider Conext SW inverter/charger
New value in off-grid solar and backup power
Schneider Conext SW delivers new value and a new price point to the marketplace. Schneider Conext SW is a pure sine wave, inverter/charger system.
Available DC switchgear panels, display control panel, remote monitoring and automated generator control modules present even more value. Stacking Schneider Conext SW units will double the power and available solar charge controllers allow for the integration of solar capacity as required.[/vc_column_text][vc_column_text]
Why choose Schneider Conext SW?
[/vc_column_text][/vc_column][vc_column width=”1/3″][contact-form-7 id=”2456″][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
Product Applications
[/vc_column_text][vc_row_inner][vc_column_inner width=”1/3″][vc_column_text]
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/3″][vc_column_text]
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/3″][vc_column_text]
[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
Device short name | SW 2524 230 | SW 4024 230 |
---|---|---|
Electrical specifications – inverter | ||
Output power (continuous) at 25°C | 2500W | 3500W |
Output power (30 min) at 25°C | 2800W | 4000W |
Output power (5 sec) at 25°C | 5000W | 7000W |
Peak current | 24.3A | 42A |
Output frequency | 50/60Hz selectable | 50/60Hz selectable |
Output voltage | 230V a.c. | 230V a.c. |
Output wave form | True sine wave | True sine wave |
Optimal efficiency | 91.5% | 92% |
Idle consumption search mode | < 8W | < 8W |
Input DC voltage range | 20 – 34V d.c. | 20 – 34V d.c. |
AC connections | Single phase | Single phase |
Electrical specifications – charger | ||
Output current | 65A | 90A |
Nominal output voltage | 24V d.c. | 24V d.c. |
Output voltage range | 12 – 32V d.c. | 12 – 32V d.c. |
Charge control | 3 stage | 3 stage |
Charge temperature compensation | Yes – BTS included | Yes – BTS included |
Optimal efficiency | 90% | 90% |
AC input power factor | > 0.98 | > 0.98 |
Input current | 10.6A | 14.0A |
Input AC voltage | 230V a.c. | 230V a.c. |
Input AC voltage range line to neutral | 170 – 270V a.c. | 170 – 270V a.c. |
Dead battery charge | Yes | Yes |
General specifications | ||
Compatible battery types | FLA, Gel, AGM, Custom | FLA, Gel, AGM, Custom |
Transfer relay rating | 30A | 30A |
Transfer time (AC to inverter and inverter to AC) |
< 1 cycle (20ms) | < 1 cycle (20ms) |
Optimal operating temperature range | -20°C to 60°C (-4°F to 140°F) |
-20°C to 60°C (-4°F to 140°F) |
Storage ambient temperature range | -40°C to 85°C (-40°F to 185°F) |
-40°C to 85°C (-40°F to 185°F) |
Product weight | 23.0kg (50.6lb) | 30.5kg (67.1lb) |
Shipping weight | 27.2kg (60.0lb) | 35.0kg (77.0lb) |
Product dimensions (H x W x D) | 38.7 x 34.3 x 19.7cm (15.2 x 13.5 x 7.6in) |
38.7 x 34.3 x 19.7cm (15.2 x 13.5 x 7.6in) |
Shipping dimensions (H x W x D) | 56.0 x 44.0 x 32.0cm (22.0 x 17.3 x 12.6in) |
56.0 x 44.0 x 32.0cm (22.0 x 17.3 x 12.6in) |
System network and remote monitoring | Available | Available |
Warranty | 5 years | 5 years |
Part number | 865-2524-61 | 865-4024-61 |
Regulatory approvals | ||
Safety | CE mark RCM mark IEC/EN62109-1, IEC/EN62109-2 |
CE mark RCM mark IEC/EN62109-1, IEC/EN62109-2 |
Specifications are subject to change without notice.[/vc_column_text][/vc_column][/vc_row]