[vc_row][vc_column width=”2/3″][vc_column_text]
PV1-F Solar Cable
Flexible Power for Solar Applications
PV1-F Solar Cable TYPICAL APPLICATIONS
Solar DC applications, DC power and garden lighting.
CONSTRUCTION
CONDUCTOR: Fine stranded tinned annealed copper to IEC 60228 Class 5&6 and AS/NZS 1125.
INSULATION: LSFLEX® R-20, Cross-linked, Thermoset, Low Smoke Zero Halogen.
SHEATH: LSFLEX® X-40, Cross-linked, Thermoset, Low Smoke Zero Halogen, Resist oil, skydrol, petrol, acid, sea water, ozone and UV. Excellent abrasion resistance. Conform to PV1-F of TUV 2Pfg 1169/08.2007.[/vc_column_text][vc_row_inner][vc_column_inner width=”1/3″][vc_column_text]
- OPERATING TEMP: -40°C to +120°C
- VOLTAGE RATING: 900/1500 Volts DC
- CORE IDENTIFICATION: To customer specification
- SHEATH COLOUR: Black or to customer specification
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/3″][vc_column_text]
STANDARDS
- AS/NZS 1125
- AS/NZS 1660.5.1
- AS/NZS 1660.5.2
- AS/NZS 1660.5.4
- AS/NZS 1660.5.6
- AS/NZS 5033
- IEC 60332-1
- IEC 60332-3-22
- IEC 60754-2
- IEC 61034-1&2
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/3″][vc_column_text]
[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][vc_column width=”1/3″][contact-form-7 id=”2456″][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]Flexible Power Cable Specifications
NUMBER OF CONDUCTORS (c) X CROSS SECTION AREA (mm2) |
NOMINAL CONDUCTOR DIAMETER (mm) |
NOMINAL HEIGHT (mm) |
NOMINAL WIDTH (mm) |
MINIMUM BENDING RADIUS (mm) |
APPROX. WEIGHT (kg/km) |
CURRENT RATING* (Amps) |
|
---|---|---|---|---|---|---|---|
2c | 4 | 2.5 | 6.9 | 11.7 | 27 | 133 | 45 |
2c | 6 | 3.1 | 7.5 | 13.0 | 30 | 176 | 57 |
2c | 10 | 4.1 | 8.5 | 17.9 | 34 | 269 | 80 |
2c | 16 | 5.1 | 9.6 | 20.2 | 39 | 380 | 105 |
2c | 25 | 6.4 | 11.3 | 23.5 | 45 | 570 | 139 |
2c | 35 | 7.8 | 12.7 | 26.5 | 51 | 766 | 172 |
*AS/NZS 3008.1.1:2009, Table 6 (Unenclosed touching – Flexible) 110oC operating temperature, ambient temperature 40oC in air 25oC in ground. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
** There is a +/- 2% tolerance to the NOMINAL value due to manufacturing process variations. Triangle Cables is not liable for any errors, omissions, etc., and reserves the right to modify specifications at any time.[/vc_column_text][/vc_column][/vc_row]