[vc_row][vc_column width=”2/3″][vc_column_text]
Power One Aurora PVI 5000 TL Outdoor
Power One Aurora PVI 6000 TL Outdoor
Designed for residential and small commercial PV installations, this inverter fills a specific niche in the Aurora product line to cater for those installations producing between 5kW and 20kW.
This inverter has all the usual Aurora benefits, including dual input section to process two strings with independent MPPT, high speed and precise MPPT algorithm for real-time power tracking and energy harvesting, as well as transformerless operation for high performance efficiencies of up to 97.0%.
The wide input voltage range makes the inverter suitable to low power installations with reduced string size. This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.
Features
- Single phase output
- Each inverter is set on specific grid codes which can be selected in the field
- Dual input sections with independent MPP tracking, allows optimal energy harvesting from two sub arrays oriented in different directions
- Wide input range
- High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting
- Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range
- Outdoor enclosure for unrestricted use under any environmental conditions
- RS-485 communication interface (for connection to laptop or datalogger)
- Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP
[/vc_column_text][/vc_column][vc_column width=”1/3″][contact-form-7 id=”2456″][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
Power One Aurora PVI 5000/6000 TL Outdoor Block Diagram
[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]
Power One Aurora PVI 5000 TL Outdoor Efficiency Curve
[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]
Power One Aurora Outdoor PVI 6000 TL Efficiency Curve
[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
Technical Data
Values | PVI-5000-OUTD-US | PVI-6000-OUTD-US | |||||
---|---|---|---|---|---|---|---|
Nominal Output Power | W | 5000 | 6000 | ||||
Maximum Output Power | W | 5000 | 6000 | ||||
Rated Grid AC Voltage | V | 208 | 240 | 277 | 208 | 240 | 277 |
Input Side (DC) | |||||||
Number of Independent MPPT Channels | 2 | 2 | |||||
Maximum Usable Power for Each Channel | W | 4000 | 4000 | ||||
Absolute Maximum Voltage (Vmax) | V | 600 | 600 | ||||
Start- Up Voltage (Vstart) | V | 200 (adj. 120-350 ) | 200 (adj. 120-350 ) | ||||
Full Power MPPT Voltage Range | V | 200-530 | 200-530 | ||||
Operating MPPT Voltage Range | V | 0.7xVstart-580 | 0.7xVstart-580 | ||||
Maximum Current (Idcmax) for both MPPT in Parallel | A | 36 | 36 | ||||
Maximum Usable Current per Channel | A | 18 | 18 | ||||
Maximum Short Circuit Current Limit per Channel | A | 22 | 22 | ||||
Number of Wire Landing Terminals Per Channel | 2 Pairs | 2 Pairs | |||||
Array Wiring Termination | Terminal Block, Pressure Clamp, AWG8 – AWG4 | ||||||
Output Side (AC) | |||||||
Grid Connection Type | 1Ø/2W | Split-Ø/3W | 1Ø/2W | 1Ø/2W | Split-Ø/3W | 1Ø/2W | |
AdjustableVoltage Range (Vmin-Vmax) | V | 183-228 | 211-264 | 244-304 | 183-228 | 211-264 | 244-304 |
Grid Frequency | Hz | 60 | 60 | ||||
Adjustable Grid Frequency Range | Hz | 57-60.5 | 57-60.5 | ||||
Maximum Current (Iacmax) | ARMS | 27 | 23 | 20 | 30 | 28 | 24 |
Power Factor | > 0.995 | > 0.995 | |||||
Total Harmonic Distortion At Rated Power | % | < 2 | < 2 | ||||
Contributory Fault Current** | Apk/ARMS | 36.25/25.63 | 36.5/25.81 | 31.75/22.45 | 36.25/25.63 | 36.5/25.81 | 31.75/22.45 |
Grid Wiring Termination Type | Terminal block, Pressure Clamp, AWG8 – AWG4 | ||||||
Protection Devices | |||||||
Input | |||||||
Reverse Polarity Protection | Yes | Yes | |||||
Over-Voltage Protection Type | Varistor, 2 for each channel | Varistor, 2 for each channel | |||||
PV Array Ground Fault Detection | Pre start-up Riso and dynamic GFDI (Requires Floating Arrays) |
Pre start-up Riso and dynamic GFDI (Requires Floating Arrays) |
|||||
Output | |||||||
Anti-Islanding Protection | Meets UL 1741/IEE1547 requirements | Meets UL 1741/IEE1547 requirements | |||||
Over-Voltage Protection Type | Varistor, 2 (L1 – L2 / L1 – G) | Varistor, 2 (L1 – L2 / L1 – G) | |||||
Maximum AC OCPD Rating | A | 35 | 30 | 25 | 40 | 35 | 30 |
Efficiency | |||||||
Maximum efficiency | % | 97.1 | 97.1 | ||||
CEC Efficiency | % | 96 | 96.5 | 96.5 | 96 | 96.5 | 96.5 |
Operating Performance | |||||||
Standy-by Consumption | WRMS | < 8 | < 8 | ||||
Night time consumption | WRMS | < 0.6 | < 0.6 | ||||
Communication | |||||||
User-Interface | 16 characters x 2 lines LCD display | ||||||
Remote Monitoring (1xRS485 incl.) | AURORA-UNIVERSAL (opt.) | ||||||
Wired Local Monitoring (1xRS485 incl.) | PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.) | ||||||
Wireless Local Monitoring | PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) | ||||||
Environmental | |||||||
Ambient Air Operating Temperature Range | °F (°C) | -13 to +140 (-25 to +60) | -13 to +140 (-25 to +60) with derating above 122 (50) |
||||
Ambient Air Storage Temperature Range | °F (°C) | -40 to 176 (-40 to +80) | -40 to 176 (-40 to +80) | ||||
Relative Humidity | % RH | 0-100 condensing | 0-100 condensing | ||||
Acoustic Noise Emission Level | db (A) @1m | < 50 | < 50 | ||||
Maximum Operating Altitude without Derating | ft(m) | 6560 (2000) | 6560 (2000) | ||||
Mechanical Specifications | |||||||
Enclosure rating | NEMA 4X | NEMA 4X | |||||
Cooling | Natural Convection | Natural Convection | |||||
Dimensions (H x W x D) | in (mm) | 41.4 x 12.8 x 8.6 (1052 x 325 x 218) | |||||
Weight | lb (kg) | < 59.5 (27.0) | < 59.5 (27.0) | ||||
Shipping Weight | lb (kg) | < 78 (35.4) | < 78 (35.4) | ||||
Mounting System | Wall bracket | Wall bracket | |||||
Conduit Connections | Trade Size Kos: (2ea x 1/2”) and (2ea x 1-1/4”, 3 places side, front, rear) |
Trade Size Kos: (2ea x 1/2”) and (2ea x 1-1/4”, 3 places side, front, rear) |
|||||
DC Switch Rating (Per Contact) | A/V | 25 / 600 | 25 / 600 | ||||
Safety | |||||||
Isolation Level | Transformerless (Floating Array) | Transformerless (Floating Array) | |||||
Safety and EMC Standard | UL 1741, CSA – C22.2 N. 107.1-01 | UL 1741, CSA – C22.2 N. 107.1-01 | |||||
Safety Approval | cCSAus | cCSAus | |||||
Warranty | |||||||
Standard Warranty | years | 10 | 10 | ||||
Extended Warranty | years | 15 & 20 | 15 & 20 | ||||
Available Models | |||||||
Standard – With DC Switch – Floating Array | PVI-5000-OUTD-US | PVI-6000-OUTD-US |