[vc_row][vc_column width=”2/3″][vc_column_text]

Power One Aurora PVI 5000 TL Outdoorpower one aurora pvi 5000
Power One Aurora PVI 6000 TL Outdoor

Designed for residential and small commercial PV installations, this inverter fills a specific niche in the Aurora product line to cater for those installations producing between 5kW and 20kW.
This inverter has all the usual Aurora benefits, including dual input section to process two strings with independent MPPT, high speed and precise MPPT algorithm for real-time power tracking and energy harvesting, as well as transformerless operation for high performance efficiencies of up to 97.0%.
The wide input voltage range makes the inverter suitable to low power installations with reduced string size. This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.

Features

  • Single phase output
  • Each inverter is set on specific grid codes which can be selected in the field
  • Dual input sections with independent MPP tracking, allows optimal energy harvesting from two sub arrays oriented in different directions
  • Wide input range
  • High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting
  • Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range
  • Outdoor enclosure for unrestricted use under any environmental conditions
  • RS-485 communication interface (for connection to laptop or datalogger)
  • Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP

[/vc_column_text][/vc_column][vc_column width=”1/3″][contact-form-7 id=”2456″][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]

Power One Aurora PVI 5000/6000 TL Outdoor Block Diagram

power one aurora pvi 5000 diagram

[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]

Power One Aurora PVI 5000 TL Outdoor Efficiency Curve

power one aurora pvi 5000 efficiency curve[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]

Power One Aurora Outdoor PVI 6000 TL Efficiency Curve

power one aurora pvi 6000 efficiency curve[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]

Technical Data

Values PVI-5000-OUTD-US PVI-6000-OUTD-US
Nominal Output Power W 5000 6000
Maximum Output Power W 5000 6000
Rated Grid AC Voltage V 208 240 277 208 240 277
Input Side (DC)
Number of Independent MPPT Channels 2 2
Maximum Usable Power for Each Channel W 4000 4000
Absolute Maximum Voltage (Vmax) V 600 600
Start- Up Voltage (Vstart) V 200 (adj. 120-350 ) 200 (adj. 120-350 )
Full Power MPPT Voltage Range V 200-530 200-530
Operating MPPT Voltage Range V 0.7xVstart-580 0.7xVstart-580
Maximum Current (Idcmax) for both MPPT in Parallel A 36 36
Maximum Usable Current per Channel A 18 18
Maximum Short Circuit Current Limit per Channel A 22 22
Number of Wire Landing Terminals Per Channel 2 Pairs 2 Pairs
Array Wiring Termination Terminal Block, Pressure Clamp, AWG8 – AWG4
Output Side (AC)
Grid Connection Type 1Ø/2W  Split-Ø/3W 1Ø/2W 1Ø/2W  Split-Ø/3W 1Ø/2W
AdjustableVoltage Range (Vmin-Vmax) V 183-228 211-264 244-304 183-228 211-264 244-304
Grid Frequency Hz 60 60
Adjustable Grid Frequency Range Hz 57-60.5 57-60.5
Maximum Current (Iacmax) ARMS 27 23 20 30 28 24
Power Factor > 0.995 > 0.995
Total Harmonic Distortion At Rated Power % < 2 < 2
Contributory Fault Current** Apk/ARMS 36.25/25.63 36.5/25.81 31.75/22.45 36.25/25.63 36.5/25.81 31.75/22.45
Grid Wiring Termination Type Terminal block, Pressure Clamp, AWG8 – AWG4
Protection Devices
Input
Reverse Polarity Protection Yes Yes
Over-Voltage Protection Type Varistor, 2 for each channel Varistor, 2 for each channel
PV Array Ground Fault Detection Pre start-up Riso and dynamic GFDI
(Requires Floating Arrays)
Pre start-up Riso and dynamic GFDI
(Requires Floating Arrays)
Output
Anti-Islanding Protection Meets UL 1741/IEE1547 requirements Meets UL 1741/IEE1547 requirements
Over-Voltage Protection Type Varistor, 2 (L1 – L2 / L1 – G) Varistor, 2 (L1 – L2 / L1 – G)
Maximum AC OCPD Rating A 35 30 25 40 35 30
Efficiency
Maximum efficiency % 97.1 97.1
CEC Efficiency % 96 96.5 96.5 96 96.5 96.5
Operating Performance
Standy-by Consumption WRMS < 8 < 8
Night time consumption WRMS < 0.6 < 0.6
Communication
User-Interface 16 characters x 2 lines LCD display
Remote Monitoring (1xRS485 incl.) AURORA-UNIVERSAL (opt.)
Wired Local Monitoring (1xRS485 incl.) PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)
Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)
Environmental
Ambient Air Operating Temperature Range °F (°C) -13 to +140 (-25 to +60) -13 to +140 (-25 to +60)
with derating above 122 (50)
Ambient Air Storage Temperature Range °F (°C) -40 to 176 (-40 to +80) -40 to 176 (-40 to +80)
Relative Humidity % RH 0-100 condensing 0-100 condensing
Acoustic Noise Emission Level db (A) @1m < 50 < 50
Maximum Operating Altitude without Derating ft(m) 6560 (2000) 6560 (2000)
Mechanical Specifications
Enclosure rating NEMA 4X NEMA 4X
Cooling Natural Convection Natural Convection
Dimensions (H x W x D) in (mm) 41.4 x 12.8 x 8.6 (1052 x 325 x 218)
Weight lb (kg) < 59.5 (27.0) < 59.5 (27.0)
Shipping Weight lb (kg) < 78 (35.4) < 78 (35.4)
Mounting System Wall bracket Wall bracket
Conduit Connections Trade Size Kos: (2ea x 1/2”)
and (2ea x 1-1/4”, 3 places side, front, rear)
Trade Size Kos: (2ea x 1/2”)
and (2ea x 1-1/4”, 3 places side, front, rear)
DC Switch Rating (Per Contact) A/V 25 / 600 25 / 600
Safety
Isolation Level Transformerless (Floating Array) Transformerless (Floating Array)
Safety and EMC Standard UL 1741, CSA – C22.2 N. 107.1-01 UL 1741, CSA – C22.2 N. 107.1-01
Safety Approval cCSAus cCSAus
Warranty
Standard Warranty years 10 10
Extended Warranty years 15 & 20 15 & 20
Available Models
Standard – With DC Switch – Floating Array PVI-5000-OUTD-US PVI-6000-OUTD-US

[/vc_column_text][/vc_column][/vc_row]