[vc_row][vc_column width=”2/3″][vc_column_text]

Fronius IG TL Inverterfronius IG TLs

Best in class with system monitoring as standard.

The Fronius IG TL combines all the benefits of a transformerless inverter with the high level of innovation and quality expected of Fronius. With power categories ranging from 3 to 5 kW, the Fronius IG TL is perfect for systems of any size from detached houses to agricultural or commercial premises. Standard system monitoring makes it the most future proof transformerless inverter on the market, and the one that will produce the most reliable yield.

  • East/west ready!
  • Improved DCAC board design
  • Night-time display for data access after daylight hours (night-time consumption less than 1w)
  • Wide input voltage range allowing a diverse range of solar array combinations
  • Accurate and efficient Maximum Power Point Tracking with the Module Manager
  • Generic USB stick can be used for easy system/data monitoring as well as inverter updating
  • String malfunction detection with built in signalling relay

[/vc_column_text][vc_row_inner][vc_column_inner width=”1/1″][vc_column_text]

Technical data

Input Data IG TL 3.0 IG TL 3.6 IG TL 4.0 IG TL 4.6 IG TL 5.0
DC maximum power at cos φ = 1 3,130 W 3,840 W 4,190 W 4,820 W 5,250 W
Max. input current (Idc max) 8.8 A 10.8 A 11.8 A 13.5 A 14.7 A
Min. input voltage (Udc min) 350 V
Feed-in start voltage (Udc start) 350 V
Nominal input voltage (Udc,r) 350 V
Max. input voltage (Udc max) 850 V
MPP voltage range (Umpp min – Umpp max) 350 V – 700 V
Number of DC inputs 6

 

Output Data IG TL 3.0 IG TL 3.6 IG TL 4.0 IG TL 4.6 IG TL 5.0
AC nominal output (P ac,r) 3,000 W 3,680 W 4,000 W 4,600 W 4,600 W1) / 5,000 W
Max. output power 3,000 W 3,680 W 4,000 W 4,600 W 5,000 W
Max. output current (Iac max) 13.0 A 16.0 A 17.4 A 20.0 A 21.7 A
Grid connection (Uac,r) 1~NPE 230 V
Min. output voltage (Uac min) 180 V
Max. output voltage (Uac max) 270 V
Frequency (fr) 50 Hz / 60 Hz
Frequency range (fmin – fmax) 46 Hz – 65 Hz
Distortion factor (50 Hz / 60 Hz) < 3% / < 3,5 %
Power factor (cos φac,r) 1

1) Fronius IG TL 5.0 devices destined for Germany, Austria, Belgium and the Czech Republic have an AC nominal output of 4,600 W.[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][vc_column width=”1/3″][contact-form-7 id=”2456″][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]

Input Data IG TL 3.0 IG TL 3.6 IG TL 4.0 IG TL 4.6 IG TL 5.0
Dimensions (height x width x depth) 597 x 413 x 195 mm
Weight 19.1 kg
Degree of protection IP 45 2)
Protection class 1
Overvoltage category (DC / AC) 2 / 3
Night-time consumption < 1 W
Inverter concept Transformerless
Cooling Regulated air cooling
Installation Indoor and outdoor installation
Ambient temperature range from –20°C – +55°C
Permitted humidity 0% – 95%
DC connection technology Screw terminal connection 2.5 mm2 – 16 mm2
AC connection technology Screw terminal connection 2.5 mm2 – 16 mm2
Certificates and compliance with standards DIN V VDE V 0126-1-1, ÖVE/ÖNORM E 8001-4-712, UTE C15-712-1, EN 50438, G83, G59, C 10 / 11, CER 06-190, Guida per le connessioni alla rete elettrica di ENEL Distribuzione, AS 4777-1, AS 4777-2, AS 4777-3

2) Please refer to the information in the operating instructions regarding correct installation of the inverter.[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]

Fronius IG TL 5.0 efficiency curve

fronius IG TL efficiency curve[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]

Fronius IG TL temperature derating

fronius ig tl temperature derating[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]

Technical data: Fronius IG TL

Efficiency IG TL 3.0 IG TL 3.6 IG TL 4.0 IG TL 4.6 IG TL 5.0
Max. efficiency 97.7 % 97.7 % 97.7 % 97.7 % 97.7 %
European efficiency (ηEU) 97.1 % 97.2 % 97.3 % 97.3 % 97.3 %
η at 5% Pac,r3) 92.1 / 87.8 % 92.6 / 88.3 % 92.9 / 88.6 % 93.1 / 89.1 % 93.4 / 89.4 %
η at 10% Pac,r3) 94.2 / 90.2 % 95.3 / 91.2 % 95.7 / 91.8 % 96.0 / 92.6 % 96.1 / 92.9 %
η at 20% P ac,r3) 96.6 / 93.6 % 96.9 / 94.2 % 97.2 / 94.5 % 97.3 / 94.8 % 97.4 / 94.9 %
η at 25% Pac,r3) 97.0 / 94.3 % 97.2 / 94.7 % 97.4 / 94.9 % 97.5 / 95.2 % 97.6 / 95.3 %
η at 30% P ac,r3) 97.3 / 94.7 % 97.4 / 95.1 % 97.5 / 95.2 % 97.6 / 95.4 % 97.6 / 95.5 %
η at 50% P ac,r3) 97.6 / 95.5 % 97.6 / 95.7 % 97.7 / 95.7 % 97.7 / 95.8 % 97.7 / 95.8 %
η at 75% Pac,r3) 97.6 / 95.8 % 97.6 / 95.8 % 97.5 / 95.7 % 97.4 / 95.7 % 97.4 / 95.6 %
η at 100% Pac,r3) 97.5 / 95.7 % 97.4 / 95.6 % 97.3 / 95.5 % 97.2 / 95.4 % 97.0 / 95.2 %
MPP adaptation efficiency > 99.9 %

3) and at Umpp min / Umpp max

Protective Equipment IG TL 3.0 IG TL 3.6 IG TL 4.0 IG TL 4.6 IG TL 5.0
DC insulation measurement Universal current-sensitive fault monitoring
Overload behaviour Operating point shift, power limitation
DC circuit breaker Integrated

 

Interfaces IG TL 3.0 IG TL 3.6 IG TL 4.0 IG TL 4.6 IG TL 5.0
USB A socket For USB sticks 4) with max. dimensions of 80 x 33 x 20 mm (l x w x h)
Signalling output 2-pin screw terminal, 12 V max. 300 mA
Two RJ45 sockets (RS485) Fronius Solar Net interface, interface protocol

4) Please refer to the information in the operating instructions regarding the use of USB sticks (temperature range).[/vc_column_text][/vc_column][/vc_row]