[vc_row][vc_column width=”2/3″][vc_column_text]
Fronius Galvo
Inverters
The future-proof inverter for small self-consumption systems.
The Fronius Galvo is a single-phase solar inverter equipped with an integrated energy management function. With power categories ranging from 1.5 to 3.1 kW, the Fronius Galvo is perfect for households – and is especially suitable for self-consumption systems. The integrated energy management relay allows the self-consumption component to be maximised. A host of other smart features make the Fronius Galvo one of the most future-proof inverters in its class: for example, the integrated datalogging, the simple connection to the internet by WLAN, or the plug-in card technology for retrofitting additional functions.
- Integrated datalogging
- Simple connection to the internet by WLAN
- Plug-in card technology for retrofitting additional functions.
- Suitable for all panel technologies (galvanic isolation)
- Low weight and compact
- Suitable for indoor and outdoor mounting
- Simple mounting system
- Automatic HF transformer switchover
- Smart Grid Ready
Technical Data
Input Data | GALVO 1.5-1 | GALVO 2.0-1 | GALVO 2.5-1 | GALVO 3.0-1 1) | GALVO 3.1-1 |
---|---|---|---|---|---|
DC maximum power at cos φ = 1 | 1,600 W | 2,140 W | 2,650 W | 3,160 W | 3,310 W |
Max. input current (Idc max) | 13.3 A | 17.8 A | 16.6 A | 19.8 A | 20.7 A |
Max. array short circuit current | 20.0 A | 26.8 A | 24.8 A | 29.6 A | 31.0 A |
Min. input voltage (Udc min) | 120 V | 165 V | |||
Feed-in start voltage (Udc start) | 120 V | 165 V | |||
Nominal input voltage (Udc,r) | 260 V | 330 V | |||
Max. input voltage (Udc max) | 420 V | 550 V | |||
MPP voltage range (Umpp min – Umpp max) | 120 – 355 V | 165 – 440 V | |||
Number of DC connections | 3 |
Output Data | GALVO 1.5-1 | GALVO 2.0-1 | GALVO 2.5-1 | GALVO 3.0-1 1) | GALVO 3.1-1 |
---|---|---|---|---|---|
AC nominal output (Pac,r) | 1,500 W | 2,000 W | 2,500 W | 3,000 W | 3,100 W |
Max. output power | 1,500 VA | 2,000 VA | 2,500 VA | 3,000 VA | 3,100 VA |
Max. output current (Iac max) | 7.2 A | 9.7 A | 12.1 A | 14.5 A | 15.0 A |
Grid connection (Uac,r) | 1~NPE 230 V | ||||
Min. output voltage (Uac min) | 180 V | ||||
Max. output voltage (Uac max) | 270 V | ||||
Frequency (fr) | 50 Hz / 60 Hz | ||||
Frequency range (fmin – fmax) | 45 – 65 Hz | ||||
Total harmonic distortion | < 4 % | ||||
Power factor (cos φac,r) | 0.85 – 1 ind. / cap. |
[/vc_column_text][/vc_column][vc_column width=”1/3″][contact-form-7 id=”2456″][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
Output Data | GALVO 1.5-1 | GALVO 2.0-1 | GALVO 2.5-1 | GALVO 3.0-1 1) | GALVO 3.1-1 |
---|---|---|---|---|---|
Dimensions (height x width x depth) | 645 x 431 x 204 mm | ||||
Weight | 16.8 kg | ||||
Degree of protection | IP 55 | ||||
Protection class | 1 | ||||
Overvoltage category (DC / AC) | 2 / 3 | ||||
Night-time consumption | < 1 W | ||||
Inverter concept | HF transformer | ||||
Cooling | Regulated air cooling | ||||
Installation | Indoor and outdoor installation | ||||
Ambient temperature range | -25 – +50 °C | ||||
Permitted humidity | 0 to 100 % | ||||
DC connection technology | Screw terminal connection 2.5 mm2 – 16 mm2 | ||||
Mains connection technology | Screw terminal connection 2.5 mm2 – 16 mm2 | ||||
Certificates and compliance with standards | ÖVE / ÖNORM E 8001-4-712, AS 4777-2, AS 4777-3, AS3100, DIN V VDE 0126-1-1/A1, VDE AR N 4105, IEC 62109-1-2, IEC 62116, IEC 61727, CER 06-190, CEI 0-21, EN 50438, G83, G59 |
1) available for countries where 3 kW restrictions apply.[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]
Fronius Galvo 3.1-1 Efficiency Curve
[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]
Fronius Galvo 3.1-1 Temperature Derating
[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
Technical Data
Efficiency | Galvo 1.5-1 | Galvo 2.0-1 | Galvo 2.5-1 | Galvo 3.0-11) | Galvo 3.1-1 |
---|---|---|---|---|---|
Max. efficiency | 95.9 % | 96.0 % | 96.1 % | ||
European efficiency (ηEU) | 94.5 % | 94.9 % | 95.2 % | 95.4 % | 95.4 % |
η at 5 % Pac,r2) | 84.5 / 86.0 / 86.0 % | 84.2 / 86.1 / 85.9 % | 88.6 / 89.6 / 89.4 % | 88.2 / 89.2 / 89.1 % | 88.4 / 89.4 / 89.4 % |
η at 10 % Pac,r2) | 87.5 / 89.7 / 89.6 % | 89.6 / 91.4 / 91.3 % | 91.2 / 92.3 / 91.4 % | 91.8 / 93.1 / 92.1 % | 91.9 / 93.3 / 92.3 % |
η at 20 % Pac,r2) | 91.3 / 93.3 / 93.1 % | 92.6 / 94.3 / 93.9 % | 94.0 / 94.8 / 94.5 % | 94.4 / 95.0 / 94.9 % | 94.5 / 95.0 / 95.0 % |
η at 25 % Pac,r2) | 92.4 / 94.1 / 93.9 % | 93.3 / 94.9 / 94.5 % | 94.5 / 95.1 / 95.0 % | 94.8 / 95.5 / 95.3 % | 94.8 / 95.5 / 95.4 % |
η at 30 % Pac,r2) | 93.0 / 94.6 / 94.3 % | 93.6 / 95.2 / 94.9 % | 94.8 / 95.5 / 95.3 % | 94.8 / 95.7 / 95.6 % | 94.9 / 95.8 / 95.6 % |
η at 50 % Pac,r2) | 93.9 / 95.5 / 95.2 % | 94.3 / 95.8 / 95.2 % | 95.0 / 95.7 / 95.2 % | 95.0 / 96.0 / 95.5 % | 95.0 / 96.1 / 95.6 % |
η at 75 % Pac,r2) | 94.2 / 95.6 / 95.4 % | 94.0 / 95.9 / 95.6 % | 94.8 / 95.9 / 95.6 % | 94.6 / 95.8 / 95.6 % | 94.5 / 95.6 / 95.6 % |
η at 100 % Pac,r2) | 94.0 / 95.9 / 95.6 % | 93.5 / 95.6 / 95.5 % | 94.4 / 95.7 / 95.5 % | 93.9 / 95.4 / 95.3 % | 93.7 / 95.2 / 95.3 % |
MPP adaptation efficiency | > 99.9 % |
Protection Devices | Galvo 1.5-1 | Galvo 2.0-1 | Galvo 2.5-1 | Galvo 3.0-11) | Galvo 3.1-1 |
---|---|---|---|---|---|
DC insulation measurement | Warning/shutdown (depending on country setup) at R ISO < 600 kOhm | ||||
Overload behavior | Operating point shift, power limitation | ||||
DC circuit breaker | Included |
Interfaces | Galvo 1.5-1 | Galvo 2.0-1 | Galvo 2.5-1 | Galvo 3.0-11) | Galvo 3.1-1 |
---|---|---|---|---|---|
WLAN / Ethernet LAN | Fronius Solar.web / Fronius Solar.web, Modbus TCP, JSON | ||||
6 inputs or 4 digital inputs/outputs | Interface to ripple control receiver | ||||
USB (A socket)3) | For USB sticks | ||||
2x RS422 (RJ45 socket)3) | Fronius Solar Net, interface protocol | ||||
Signalling output3) | Energy management (potential-free relay output) | ||||
Datalogger and Webserver | Included |
1) available for countries where 3 kW restrictions apply. 2) and at Umpp min / Udc,r / Umpp max. 3) also available in the light version.[/vc_column_text][/vc_column][/vc_row]