[vc_row][vc_column width=”2/3″][vc_column_text]
Power One Aurora UNO 2.0 and 2.5
The Power One aurora UNO-2.0-I and UNO-2.5-I are the latest single phase string inverters in the Aurora range. A new-look inverter but packed with Power-One’s proven high performing technology. The new look inverter has new features including a special built-in heat sink compartment and front panel display system.
The smallest of Power-One’s outdoor range, these new products are the right size for the average rooftop installation. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.
The high speed MPPT offers real-time power tracking and improved energy harvesting.
Despite the isolated operation, the Power One Aurora UNO-2.0-I and UNO-2.5-I feature an efficiency of 96.3%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size.
Features
- Each inverter is set on specific grid codes which can be selected in the field
- Single phase output
- Wide input range
- High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting
- Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable prformance across the entire input voltage and output power range
- Outdoor enclosure for unrestricted use under any environmental conditions
- RS-485 communication interface (for connection to laptop or datalogger)
- Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP
[/vc_column_text][/vc_column][vc_column width=”1/3″][contact-form-7 id=”2456″][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
Block Diagram of UNO-2.0-I and UNO-2.5-I
[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]
UNO-2.0-I-OUTD Efficiency Curve
[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]
UNO-2.5-I-OUTD Efficiency Curve
[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]
Product Specifications
| UNO-2.0-I-OUTD | UNO-2.5-I-OUTD | |
|---|---|---|
| Input Side | ||
| Absolute Maximum DC Input Voltage (Vmax,abs) | 520 V | |
| Start-up DC Input Voltage (Vstart) | 200 V (adj. 120…350 V) | |
| Operating DC Input Voltage Range (Vdcmin…Vdcmax) | 0.7 x Vstart …520 V | |
| Rated DC Input Power (Pdcr) | 2100 W | 2600 W |
| Number of Independent MPPT | 1 | |
| Maximum DC Input Power for each MPPT (PMPPTmax) | 2100 W Linear Derating From MAX to Null [530V≤VMPPT ≤580V] |
2600 W Linear Derating From MAX to Null [530V≤VMPPT ≤580V] |
| MPPT Input DC Voltage Range (VMPPTmin,f … VMPPTmax,f) at Pacr | 165…470V | 205…470V |
| DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example |
Not applicable | |
| Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) | 12.8 A / 12.8 A | |
| Maximum Input Short Circuit Current for each MPPT | 16.0 A | |
| Number of DC Inputs Pairs for each MPPT | 2 | |
| DC Connection Type | Tool Free PV Connector WM / MC4 | |
| Input Protection | ||
| Reverse Polarity protection | Yes, from limited current source | |
| Input Over Voltage Protection for each MPPT – Varistor | 2 | |
| Photovoltaic Array Isolation Control | According to local standard | |
| DC Switch Rating for each MPPT (-S Version) | 16 A / 600 V | |
| Output Side | ||
| AC Grid Connection Type | Single phase | |
| Rated AC Power (Pacr) | 2000 W | 2500 W |
| Maximum AC Output Power (Pacmax) | 2200 W | 2750 W |
| Rated AC Grid Voltage (Vac,r) | 230 V | |
| AC Voltage Range | 180…264 V(1) | |
| Maximum AC Output Current (Iac,max) | 10.0 A | 12.0 A |
| Rated Output Frequency (fr) | 50 Hz | |
| Output Frequency Range (fmin…fmax) | 47…53 Hz (2) | |
| Nominal Power Factor (Cosphiac,r) | > 0.995 (adj. ± 0.95) | |
| Total Current Harmonic Distortion | < 3% | |
| AC Connection Type | Screw terminal block | |
| Output Protection | ||
| Anti-Islanding Protection | According to local standard | |
| Maximum AC Overcurrent Protection | 15.0 A | |
| Output Overvoltage Protection – Varistor | 2 (L – N / L – PE) | |
| Operating Performance | ||
| Maximum Efficiency (ηmax) | 96.3% | |
| Weighted Efficiency (EURO/CEC) | 96.0% / – | |
| Feed In Power Threshold | 24.0 W | |
| Stand-by Consumption | < 8.0 W | |
| Communication | ||
| Wired Local Monitoring | PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.) | |
| Remote Monitoring | PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) | |
| Wireless Local Monitoring | PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) | |
| User Interface | Graphic display | |
| Environmental | ||
| Ambient Temperature Range | -25…+60°C (-13…+ 140°F) with derating above 45°C (113°F) | |
| Relative Humidity | 0…100 % condensing | |
| Noise Emission | < 50 db(A) @ 1 m | |
| Maximum Operating Altitude without Derating | 2000 m / 6560 ft | |
| Physical | ||
| Environmental Protection Rating | IP 65 | |
| Cooling | Natural | |
| Dimension (H x W x D) | 518mm x 367mm x 160mm / 20.4” x 14.4” x 6.3” | |
| Weight | < 17 kg / 37.4 lb | |
| Mounting System | Wall bracket | |
| Safety | ||
| Isolation Level | HF transformer | |
| Marking | CE | |
| Safety and EMC Standard | EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-1, EN61000-6-3, EN61000-3-11, EN61000-3-12 |
|
| Grid Standard | Enel Guideline, VDE 0126-1-1, G83/1, EN 50438, RD1663, AS 4777 | |
| Available Products Variants | ||
| With DC Switch | UNI-2.0-I-OUTD-S | UNI-2.5-I-OUTD-S |
1. The AC voltage range may vary depending on specific country grid standard
2. The Frequency range may vary depending on specific country grid standard[/vc_column_text][/vc_column][/vc_row]